Asbestos TEM analysis, World Trade Center, Sep 2001

Machine-extracted title · confidence 45%

TEM asbestos fiber analysis report for World Trade Center site, AHERA/SAED/EDS methods, dated 09/17/01.

NYC-WTC_000431339
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 NYC School Construction Authority Approved N.Y. State ELAP #10879 I 30-30 Thomson Avenue Long Island City, NY 11101 ACCREDITED NVLAP Lab Code # 1187 Report Date: 09/17/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) I .With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

I Sample Identification Analysis Parameters

Pr0ject/Site: Worldjrrad€Center,,NY^^^ TEM Sample No.: 5515 ~ 59044

I Personal Monitoring Date Received: Q9/I7/01 Grid Openings Analyzed: IQ

I Project Sample No.: 020 Average Grid Opening: 106.00 um

Air Volume: 210 liters Total Area Analyzed: 0.1124 mm2

H Filter Typ e: MCE 25 mm diam. , Pore Size.- Q.45.ufn Analytical Sensitivity:8.;9 s/mm2 ® Effective Area-. 385 mm2 0.0163 s/cc

I FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct ‘Sum Struct/mm2 Struct/cc ngm/m3

H Chrysotile Asbestos 17 10 2 4 6 151.2 0.2773 ' 9150

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0 H Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 17 6 151.2 0.2773 9150 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

I Totals (All Structures) The estimated uncertainty of Chis analysis is 1 standard deviation. 17 6 151.2 0.2773 K/A

Non-asbestos fiber i.d. (EDS/STVED) : None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method.

I This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by: I Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_010237396

NYC-WTC_000431339

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000431339Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →