Chain of Custody, Stuyvesant HS cleanup

Machine-extracted title · confidence 42%

CoC documenting air-monitoring setup and tent construction for classroom cleanup at Stuyvesant High School, M477-15217-29881.

NYC-WTC_000430080–000430081
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I I Taylor environmental grour inc. I Stuyvesant High School Chambers Street, New York, NY

I SCA Project #:M477-15217, LLW#; 29881

Scope of Work/Sampling Protocol for Clean-Up of Unit Ventilator's I Contractor: Kiss Construction, Inc.

I 1. TDX is to disconnect and open external cover of Unit Ventilator's in classroom 2. Kiss Construction will construct tent (1 layer 6 mil poly) around all Unit

I Ventilator's within classroom. Kiss will use HEPA vacuum as negative air 3. Lead Personal Air Monitoring (IWA)

I When Kiss starts building tent in each classroom, calibrate personal pump with lead cassette to 2 L/min and put on one worker. Write Workers Name, SS Number, and Room Number on Chain of Custody. Examp/s: If Kiss are bui/ding tents in four (4} ciassrooms, Tayior i/viii be sampiing 4 (four) different workers, (one in each ciassroom/tentj Change cassette(s) on worker(s) every 4 (four) hours. 2 (two) samples per worker per shift I (Minimum Volume - 200L) - (100 Min @ 2 MMin) (Maximum Volume - 1500L) - (750 Min @ 2 L/Min) I 4. Lead Ambient (outside tent) Air Monitoring (OWA) When Kiss start building tent in each classroom, calibrate high volume (AC) I pump to 2 L/Min with lead cassette, use stand (5' High) and position pump away from tent inside classroom near entrance to corridor/hallway. Collect 1 (one) sample for duration of shift (~8 hours) (Same minimum/maximum volumes as for personals)

I At conclusion of sampling, collect air-samples (check final flow rates): personals and ambients (collect 10% or minimum of 2 field blanks per batch) and drop off samples to lab (ATC) for 12 hour turnaround time (not 6 hour: wipes only) I AiOTE: For aii iead air sampies write AJIOSH Fietbod 7082 on Chain of Custody and 12 hour turnaround time in Comments Section.

I 5. Kiss will clean Unit Ventilator's within tent enclosure. Taylor will perform visual inspection of Unit Ventilator's and interior of tent to ensure no-dust remains.

I Page 1 of 2 130A JERICHO TPKE., FLORAL PARK, NY 11001 ■ PHONE (516) 358-2955 - FAX (516) 358-1780

CITY_21MC100_0 10218295

NYC-WTC_000430080

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000430080Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Chain of Custody, Stuyvesant HS cleanup

NYC-WTC_000430078

CoC form detailing contractor cleanup scope and air monitoring setup at Stuyvesant High School, M477-15217, LLW 29881.

Similar indexed content

Compare copies and versions →