Tent enclosure cleaning visual inspection plan, 2002

Machine-extracted title · confidence 38%

Procedure for visual inspection and cleaning of tent enclosures during renovation.

NYC-WTC_000429995
Page image
Scanned page image, NYC-WTC_000429995
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Prior to dismantling each tent enclosure TEG persormel will conduct a thorough visual inspection of each Unit Ventilator (including the interior surfaces of the tent enclosure) to ensure that no visible dust/debris remain. In the event that dust/debris is observed then the environmental contractor will be directed to perform additional cleaning prior to an further visual inspection.

Air Monitoring/Wipe Sampling and Analytical services:

In order to evaluate possible levels of airbome-lead particles, if any, generated during the environmental cleaning procedure, TEG recommends that Personal (OSHA) Air-Monitoring be performed on the environmental contractors personnel while working inside the tent enclosures. All personal air samples will be collected and analyzed in strict accordance with NIOSH Method 7082.

At the conclusion of the re-installation of all Unit Ventilators within a specific functional space, a visual inspection of the space shall be performed by TEG personnel to ensure that no visible dust/debris are present. In the event that dusVdebris are observed then the mechanical and/or environmental contractor shall be directed to re-clean the space.

After the space has passed a thorough visual inspection and before returning it to the school for reoccupancy, a TEG EPA Certified Lead Inspector shall collect wipe samples to be analyzed for lead in accordance with NYC SCA Wipe-Sampling Protocols (minimum of three wipe samples plus field blanks per functional space). All wipe samples will be analyzed via EPA Method SW846- 7420.

In the event that the results of any one wipe sample exceeds US EPA clearance levels for lead, then the space shall be re-cleaned and further wipe sampling performed until the results of all samples collected within the space are below US EPA clearance requirements.

If you have any questions, or require further information, please do not hesitate to call. I hope we have satisfactorily assisted you in your environmental health concerns.

Sincerely,

Georgt/^iylor Laboratory Director Taylor Environmental Group, Inc.

CITY_21MC100_010218133

NYC-WTC_000429995

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000429995Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000434664

Summary of cleaning and testing work at Stuyvesant High School following elevator/ventilation inspections.

Similar indexed content

NYC-WTC_000429996

Summary memo detailing project team and partner firms for Stuyvesant High School work, Aug 2002.

Similar indexed content

Compare copies and versions →