NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 10 pages

Ambient Air Monitoring Plan Comments, Aug 2005

Machine-extracted title · confidence 66%

Section 2 comments re criteria for ambient air monitoring plan, June-Aug 2005.

NYC-WTC_000428441–000428450
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

analyses was planned for the analyses of this single parameter. In light of this and the EPA suggestion LMDC has elected to use ICP-MS in concert with high volume air sampling. This approach will provide optimum detection limits for all target parameters through use of a single analytical technique.

19. The plan does not indicate how particulate phase mercury will be collected. This information needs to be stated in this subsection.

Section 4 of the June 2005 Air Monitoring Program incorrectly used the term particulate phase mercury in reference to target parameters. Sections 5 and 6 of this same document correctly referred to both gaseous and total (gas and particulate combined) mercury as target parameters which will be measured as part of the 130 Liberty Street Monitoring Program. Vapor only mercury concentrations will be measured with the Lumex analyzer while total mercury concentrations will be measured with iodated carbon traps in concert with cold vapor atomic fluorescence (CVAF). This represents a more rigorous and comprehensive approach for mercury monitoring than was used in the monitoring program for 4 Albany Street.

20. Please ensure that the Met One E- BAM utilized includes a heated inlet to address condensible emissions.

The Met One EBAM inlets will be heated albeit indirectly. The manufacturer Met One further has informed TRC that the EBAM inlets are indirectly heated by air that comes from within the unit. This air is heated by exposure to the instrument internal pumping system and then passed over the sampler inlet such that the inlet temperature is maintained at a variable temperature above ambient (typically 3-5 degrees C above the outside ambient temperature). It should be noted that the EBAM is not designated as an EPA Reference Method Sampler or Equivalent for either PM10orPM2.5.

21. Table 2 (Summary of Sampling and Analyses Methods) discusses sampling rates for various analytes. LMDC states that the sampling rate for respirable crystalline silica and dust will be 2.5 liters per minute (1pm) collected over a 24-hour integrated time period using sampling method NIOSH 0600/7500. NIOSH methods 0600 and 7500 indicate that its maximum sampling volumes are 400 and 1000 liters, respectively. Please explain if the LMDC proposed sampling rate collected over a 24-hour period will exceed the NIOSH maximum volume. If so, explain the reasons that the proposed sampling rate will be sufficient for the sampling and analysis of this analyte. This same question also applies to the proposed sampling rate (1000 1pm) for the metals in comparison to the working range specified in 40 CFR Part 50 App. B.

Based on the comment and discussions with the laboratory, the decision was made to reduce the flow rate from 2.5 liters per minute to 2-2.1 liters per minute and to reduce the sampling time for silica analysis to 8 hours which would be consistent with the asbestos sampling and also more consistent with the NIOSH methodologies being

7

C ITY_D E P_WO RB Y_C AN N ATA_SU B P_000114764

NYC-WTC_000428447

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000428447Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427338

Section 2 comments re criteria for ambient air monitoring plan, June-Aug 2005.

Similar indexed content

Compare copies and versions →