NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 8
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 49 of 116
handling, and sample preservation techniques are used. Refer to Section 10.1 of the QAPP for
the sampling design which will provide representative data over the site. Representativeness may
also be assessed by the use of field duplicate samples. By definition, field duplicate samples are
collected so they are equally representative of a given point in space and time. In this way, they
provide both precision and representativeness information. As stated previously, field duplicate
samples will generally be collected at a frequency of one per week per analytical parameter.
In general, representativeness in the field will be maximized by following the reference sampling
methodologies, proper sample preservation procedures, utilizing experienced/trained sampling
crews, and conducting field audits.
Measures to Ensure Representativeness of Laboratory Data
Representativeness in the laboratory is ensured by using the proper analytical procedures,
appropriate methods, and meeting sample holding times. Following the detailed requirements
outlined in the EPA and NIOSH methods will maximize the representativeness of the laboratory
data.
8.2.4 Comparability
Comparability is a qualitative parameter that expresses the confidence with which one data set
can be compared to another.
Measures to Ensure Field Comparability
Comparability is dependent upon the proper design of the sampling program and will be satisfied
by ensuring that the QAPP is followed, sampling and analytical methodologies are followed, and
that proper sampling and preservation techniques are used.
Measures to Ensure Laboratory Comparability
Comparability is dependent on the use of EPA and NIOSH methods and the reporting of data in
standardized units.
8.2.5 Sensitivity
Sensitivity is the ability of the instrument or method to detect the contaminants of concern at the
level of interest.
Quantitation Limits
Table 8-1 outlines the required quantitation limits for each matrix, each analytical parameter and
each analyte. These quantitation limits are significantly below the project Action Limits. In
almost all cases, EPA or NIOSH methodologies were selected with specific requirements or
L2005-346 Rev. 1
CITY DEP WORBY CANNATA SUBP 000114690
NYC-WTC_000428373