NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 6
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 24 of 116
6.3.3 USEPA Site Specific Trigger Levels
6.3.3.1 Definition of Exceedances
Any 24-hour value (eight-hour value in the case of asbestos and silica) in excess of the USEPA
Site Specific Trigger Level will be considered an “exceedance” and the actions described below
will be taken.
6.3.3.2 Actions Based on Exceedances
Exceedance of USEPA Site Specific Trigger Eevels will result in a stoppage of work associated
with the exceedance until an evaluation of emission controls is performed and corrective action
is in place. The USEPA Site Specific Trigger Levels are applicable to individual sample results.
If any of the individual sample results exceed an USEPA Site Specific Trigger Level, then
notification must be made to the USEPA Region 2, NYCDEP, NYSDOL and NYSDEC. Work
will be reinitiated once the USEPA Region 2 has agreed (and NYSDOL during the Abatement
Phase in the case of asbestos exceedances) to the corrective action(s) proposed to prevent the
potential for exceedances in future work and such corrective actions have been implemented.
LMDC will monitor PMio and PM2.5 at each station in the network on a continuous basis. These
data will be reviewed on a routine basis during the course of each 24 hour monitoring period and
used to alert LMDC of any potential exceedances of 24 hour action levels established for these
parameters. Corrective actions will be taken as needed during the course of the work when
warranted from review of the continuous monitoring data.
L2005-346 Rev. 1
CITY_DEP_WORBY_CANNATA_SUBP_000114665
NYC-WTC_000428348
OCR can misread numbers and units. Confirm readings against the page image before using them.