NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 6
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 22 of 116
• Collect particulate matter on a time-weighted or integrated basis such that samples are
available for monitoring of target compounds potentially associated with World Trade Center
dust (e.g., asbestos, lead).
• Compare measured concentrations of project target parameters to action levels established on
a compound-specific basis. In the event that measured concentrations exceed any project
specific action level for one or more of these target compounds, appropriate corrective
actions immediately will be taken.
6.3 Project Action Levels
A two tiered system will be in place during the entire term of the deconstruction project. This
system includes use of both Target Air Quality Levels and USEPA Site Specific Trigger Levels
for each of the target parameters. A summary listing of the Action Levels provided on a
parameter-specific basis is shown in Table 6-1.
Table 6-1. Target Air Quality Levels and USEPA Site Trigger Levels
USEPA Site Specific
Analyte Target Air Quality Levels^
Trigger Levels^
Metals
Antimony 5 ug/m" 14 ug/m"
Barium 5 ug/m" 5 ug/m"
Beryllium 0.02 Ug/m" 0.2 ug/m"
Cadmium 0.04 ug/m" 2 ug/m"
Chromium" 0.6 ug/m" 0.6 ug/m"
Copper 10 ug/m" 100 ug/m'
Lead 1.5 ug/m' 5 ug/m"
Manganese 0.5 ug/m' 0.5 ug/rn"
Mercury (Total) 0.3 ug/m' 3 ug/m"
Nickel 0.2 ug/m' 28 ug/m"
Zinc 16 ug/m" 160 ug/m'
Particles and Dust
Asbestos 0.0009 f/cc (PCME fibers) 70 S/mm" (TEM AHERA
structures)
Particulate PM 10 (24 hour average) 150 ug/m' _______ 150 ug/m'______
Particulate PM2 5 (24 hour average) 40 ug/m" _______ 65 ug/m"_______
Respirable Silica (crystalline) 10 ug/m" 10 ug/m"
Organics (semi-volatiles)
Dioxins/Furans (2,3,7,8 - TCDD equivalent) 0.00025 ng/m 0.025 ng/m
PCB (total Aroclors )____________________ 0.12 ng/m' 12 ug/m^
PAH (benzo-a-pyrene equivalent) 0.034 iig/iii
‘a cumulative average after the first week of sampling, except for PM2.5 and PMio.
A 24-hour value.
^USEPA sitc-spccific trigger level for hexavalent chromium used.
L2005-346 Rev. 1
CITY_DEP_WORBY_CANNATA_SUBP_000114663
NYC-WTC_000428346