NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 14
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 103 of 116
Dioxin/Furan Congener TEF
1,2,3,6,7,8-HxCDF____________ 0.10
2,3,4,6,7,8-HxCDF____________ 0.10
1,2,3,7,8,9-HxCDF____________ 0.10
1,2,3,7,8,9-HxCDD___________ 0.10
1,2,3,4,6,7,8-HpCDF__________ 0.01
1,2,3,4,7,8,9-HpCDF 0.01
1,2,3,4,6,7,8-HpCDD__________ 0.01
OCDD_____________________ 0.001
OCDF 0.001
14.5.2.2 PAH Transformation and Reduction
The laboratory will be responsible for calculating the benzo(a)pyrene-equivalent (BAP-
equivalent) concentration for each sample. The BAP-equivalent concentration will be calculated
using potency equivalency factors (PEFs) from the Office of Environmental Hazard Assessment
(OEHHA). Each carcinogenic PAH is multiplied by the associated PEE. The resulting values
from each carcinogenic PAH are summed to generate the BAP-equivalent concentration. In
order to remain conservative, the quantitation limit for nondetect results will be used in the BAP-
equivalent concentration calculation. The PEFs which will be used are as follows:
Carcinogenic PAH ■I
Benzo(a)anthracene_________ 0.1
Chrysene 0.01
Benzo(b)fluoranthene_______ 0.1
Benzo(k)fluoranthene 0.1
Benzo(a)pyrene 1.0
Indcno(l,2,3-cd)pyrcnc______ 0.1
Dibenz(a,h)anthracene 1.1
14.5.2.3 PCB Reduction
The laboratory will be responsible for calculating the total PCB concentration based on the
Aroclor results. If all Aroclors are reported as nondetects, the total PCB results will be
equivalent to the quantitation limit of one individual Aroclor. If one or more Aroclors are
detected, the total PCB concentration will be calculating by summing only the detected Aroclors.
14.5.3 Data Transfer and Transmittal
Hard copy and HDDs from the laboratories will be transmitted to the TRC Project QA Officer
upon completion of analysis, who will forward all deliverables to the TRC Project Manager.
Copies of these transmittals will be forwarded to the TRC Project Manager for storage in the
L2005-346 Rev. 1
C ITY_D E P_WO RB Y_C AN N ATA_SU B P_000114744
NYC-WTC_000428427
OCR can misread numbers and units. Confirm readings against the page image before using them.