Ambient Air Monitoring Program Section No. 14
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 102 of 116
the Target Air Quality Levels, 3x the Target Air Quality Levels, and the USEPA Site-Specific
Trigger Levels. The laboratory will calculate all results using sample volumes provided by TRC.
A cumulative average will be generated after the first week of sampling. Results will
subsequently be compared and rolled into this cumulative average. Daily summaries of all
results will be posed on the LMDC’s website.
The spreadsheets associated with dioxin/furan results will include speciated results for each
dioxin/furan congener, the TEFs used, and the TEQ. The spreadsheets associated with PAH
results will include speciated results for each target PAH, the BAP-factors used, and the BAP-
equivalent concentration. The spreadsheets associated with PCB results will include the results
for individual Aroclors as well as the result for total PCBs.
14.5 Data Handling and Management
14.5.1 Data Entry and Verification
All data entry performed by TRC or its contractors will be proofed 100% for accuracy.
Verification will be earned out either by proofing a printout against the original data or by
duplicate entry and comparison of the two data sets to detect discrepancies.
14.5.2 Data Transformation and Reduction
14.5.2.1 Dioxins/Furans Transformation and Reduction
The laboratory will be responsible for calculating the toxicity equivalent quotient (TEQ) for each
sample. The TEQ will be calculated using toxicity equivalency factors (TEFs) from Interim
Procedures for Estimating Risks Associated With Exposure to Mixtures of Chlorinated Dibenzo-
p-Dioxin and Dibenzofurans (CDDs/ CDFs), EPA-625/3-89-016, March 1989. Each dioxin or
furan congener is multiplied by the associated TEE. The resulting values from each congener are
summed to generate the TEQ. In order to remain conservative, the detection limit for nondetect
results will be used and estimated maximum possible concentrations (EMPCs) will be included
in the calculations. The TEFs which will be used are as follows:
______ Dioxin/Furan Congener
2,3,7,8-TCDD_______________ 1.00
2,3,7,8-TCDF_______________ O.l
1,2,3,7,8-PeCDD_____________ 0.50
L2,3,7,8-PeCDF_____________ 0.05
2,3,4,7,8-PeCDF_____________ 0.5
L2.3.4.7^8-HxCDD___________ 0.10
L2,3,6,7,8-HxCDD___________ 0.10
1,2,3,4,7,8-HxCDF 0.10
L2005-346 Rev. 1
C ITY_D E P_WO RB Y_C AN N ATA_SU B P_000114743
NYC-WTC_000428426