NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
in the appropriate, clean, laboratory-prepared sample containers and analyzed for the
same parameters.
Precision for laboratory and field measurements will be expressed as the relative percent
difference between two duplicate determinations. Acceptance criteria for laboratory
precision will be those specified in the method or +/- 20 percent if not otherwise stated
Data validation will be carried out upon receipt of all laboratory documents. Sample results will
be evaluated to assess potential usability issues. The reported results of all QC checks and
analytical procedures will evaluated, including holding times, sample preservation techniques,
QC sample results, etc. QC samples reviewed to identify potential problems in any of three
specific areas: laboratory/instrument performance, sample preparation/matrix effects, and field
performance. Laboratory and instrument performance will evaluated by reviewing laboratory
blank contamination and instrument calibration data provided by the laboratory. Any unusual
matrix effects will be detected by examining the results from matrix spike/matrix spike
duplicates, sun'ogate spike recoveries, and internal standard responses as reported by the
laboratory.
Potential problems originating from field sampling work will be
evaluated by examining the field duplicate, equipment blank, and trip blank results.
If the evaluation of QC checks indicate laboratory or field problems, then their impact on the data
will be reported with the sample results.
Before reporting results, raw data will be reviewed in detail to verify the accuracy of the results
reported by the laboratory.
More detailed information is available from individual SOPs for the test of interest or the
published method.
Table 10-1
RCRA Waste Characterization Analytical Method, Container, Preservation and Holding
Times for selected aqueous and non-aqueous matrices.
Min Conta/ner Sample Holding
Ana/yte Met/ioe/ volume Type Preservatio Time
(mL) n
Acidity_________ EPA 305.1/ SM 2310 B 1000 P,G Cool, 4 °C 14 days
Alkalinity EPA 310.1/ SM 2320 B 1000 P,G Cool, 4 °C 14 days
Chlorinated EPA 608/ SW 8080 1000 GA Cool, 4 °C 7/14
Pesticides and days
PCB’s
Corrosivity SW846 Metliod 9045D or 9040C 500 P, G, Cool, 4 °C immed
Flame AA Metals SW 7000/ 500 P HNO3 pH<2 6 mo
GFAA Metals SW 7000/_________________ 500 P HNO3 pH<2 6 mo
Hexavalent SW7186 500 P,G Cool, 4 °C 24 hr
Chromium
ICP Metals SW 846 Method 601 OB or 6020 500 P HNO3 pH<2 6 mo