Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
Ignitability ASTM D-93-79 or D-93-80 100 g G Cool, 4 °C 28 days
(Flashpoint) or D-3278-78.
Mercury EPA 245.1/ SM3112B/ 500 P HNOa pH<2 6 mo
SW846 Method 7470A
PAH SW 8100____________ 1000 GA Cool, 4 °C 7/40days
PAH SW 8310 1000 GA Cool, 4 °C 7/30
days
PCB EPA 608/ SW 8082 1000 GA Cool, 4 °C 7/40
days
pH EPA 150.1/ SW9040 B/ 500 P,G Cool, 4 °C immed
Reactive Cyanide SW 9012 A, 7.3 1000 P,G Cool, 4 °C 14 days
Reactive Sulfide SW 9030 B/9034 500 P,G zinc acetate, 7 days
NaOH pH>9
I'CLP Semivolatile EPA 625/ SW 3510 C/ 8270C 1000 GA Cool, 4 °C 7/40
Organics days
TCEP Volatile EPASW846-1311/8260B 1000 GA Cool, 4 °C 7/40
Organics days
I'CLP Pesticide SW846 Method 8081A 1000 GA Cool, 4 °C 7/40
days
TCEP Herbicide SW846 Metliod8151A 1000 GA Cool, 4 °C
days
P = plastic, HOPE G= glass GA= amber glass VOA = 40 mL vial
Preservation should be performed at time of sample collection. Sample bottles with or without preservative
may be obtained by contacting the laboratory. Indication of preservative would be helpful either on the
label or a sample chain of custody (also available from the laboratory). The holding times listed in the table
are the maximum allowable time a sample can be held before analysis and still be in compliance with the
EPA regulations. Sample collection date and time aie needed to ensure that holding times aie met properly.
10.3 Field Quality Control
This section of the QAPP identifies the QC procedures, checks, samples, and their
respective acceptance limits, that will be used to monitor the quality of various aspects of
the sampling event. Their required analysis frequency, acceptance limits and corrective
actions are also documented in this section of the QAPP.
10.3.1 Field Blanks/Trip Blanks
Field/trip blanks consist of clean sample media. Field/trip blanks accompany samples to
the site and return to the laboratory in the same cooler or shipping container. Field/trip
blanks will be used to ensure that there is no contamination as a result of the
shipment/transportation/on-site storage activities. Field/trip blanks will be collected for
all parameters associated with air samples. Field/trip blanks for asbestos and silica will
only be analyzed if the asbestos or silica are detected in the associated samples.
10.3.2 Cooler Temperature Blanks
69
CITY_DEP_WORBY_CANNATA_SUBP_000093257
NYC-WTC_000427025