Part V - Quality Assurance Project Plan 133-135 Greenwich Streel/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - January 27, 2006

for hazardous materials shipments). Samples will be prepared and shipped to the laboratory according to the following procedures:

1. All sample jars, once cleaned and labeled, will be placed in clean plastic re- sealable bags. Medium or high concentration samples (determined through field obsei-vations, field screening, air monitoring, or all three) will also be packaged in metal cans. The lids of the metal cans will be secured with at least three metal lid clips. The exterior of the metal cans will be labeled in the same fashion as the sample jar. 2. Place samples in a cooler and surround them with vermiculite (or equivalent) packing material for moisture absorption and stability during transport. 3. Place sufficient double-bagged ice in the cooler to maintain 4°C temperature. 4. Place a "temperature blank", consisting of a water-filled plastic container, in each cooler. The temperature blank will be recorded by the laboratory upon receipt to ensure adequate sample temperature. 5. Place completed COC form inside a re-sealable plastic bag, and tape the bag to the inside of the cooler lid. 6. Secure the cooler lid with packing tape. Place signed and dated custody seals on two opposite sides of the lid and secure with clear tape. 7. If applicable, tape the drain plug closed so that it will not open. 8. Place upward-pointing arrow label on two opposing vertical sides of the cooler. 9. Label the cooler with laboratory address, name of laboratory contact, telephone number, and project identification. 10. Attach applicable IATA and/or DOT identification labels. 11. Attach a completed courier shipping label (if applicable).

Samples will be classified as environmental samples unless there is evidence of high concentrations of chemical constituents, based on visual observations, odors, previous sample data, or other criteria. All waste liquid, waste solid, tank, drum, and other container samples will be considered hazardous material samples and will be packaged and transported in conformance with the U.S. DOT, U.S. Postal Service (USPS), and the IATA Dangerous Goods Regulations if shipped by air carrier. These regulations/requirements have de minimus exemptions for small volume samples; they will be referred to prior sample shipment to ensure all requirements are being met.

The United States Environmental Protection Agency’s Environmental Response Team (EPA ERT) publishes sampling SOPs for sampling at CERCLA hazardous waste sites. These SOPs will be followed during the sampling at this site.

QA/QC samples will be collected to assist in the inteipretation and validation of the laboratory analytical results. The QA/QC samples that will be collected during this characterization sampling program include field duplicates or co-located samples (10 percent of samples). Field duplicate samples will be collected as a check on laboratory accuracy and precision. One duplicate dust sample will be collected from the bulk dust and or high-efficiency particulate air (HEPA) filters. The duplicate sample will be placed

67

CITY_DEP_WORBY_CANNATA_SUBP_000093255

NYC-WTC_000427023

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427023Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000425068

Title and approval sheet for Environmental Community Air Monitoring Program and plan at Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000427415

CoC document detailing plan for Environmental Community Air Monitoring at Greenwich Street sites.

Similar indexed content

NYC-WTC_000424476

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000426688

Plan document for environmental community air monitoring at Greenwich/Thames sites, Sept 2005.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →