NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
for hazardous materials shipments). Samples will be prepared and shipped to the
laboratory according to the following procedures:
1. All sample jars, once cleaned and labeled, will be placed in clean plastic re-
sealable bags. Medium or high concentration samples (determined through field
obserx^ations, field screening, air monitoring, or all three) will also be packaged in
metal cans. The lids of the metal cans will be secured with at least three metal lid
clips. The exterior of the metal cans will be labeled in the same fashion as the
sample jar.
2. Place samples in a cooler and surround them with vermiculite (or equivalent)
packing material for moisture absorption and stability during transport.
3. Place sufficient double-bagged ice in the cooler to maintain 4°C temperature.
4. Place a "temperature blank", consisting of a water-filled plastic container, in each
cooler. The temperature blank will be recorded by the laboratory upon receipt to
ensure adequate sample temperature.
5. Place completed COC form inside a re-sealable plastic bag, and tape the bag to
the inside of the cooler lid.
6. Secure the cooler lid with packing tape. Place signed and dated custody seals on
two opposite sides of the lid and secure with clear tape.
7. If applicable, tape the drain plug closed so that it will not open.
8. Place upward-pointing arrow label on two opposing vertical sides of the cooler.
9. Label the cooler with laboratory address, name of laboratory contact, telephone
number, and project identification.
10. Attach applicable IATA and/or DOT identification labels.
11. Attach a completed courier shipping label (if applicable).
Samples will be classified as environmental samples unless there is evidence of high
concentrations of chemical constituents, based on visual observations, odors, previous
sample data, or other criteria. All waste liquid, waste solid, tank, drum, and other
container samples will be considered hazardous material samples and will be packaged
and transported in conformance with the U.S. DOT, U.S. Postal Seiwice (USPS), and the
IATA Dangerous Goods Regulations if shipped by air carrier. These
regulations/requirements have de minimus exemptions for small volume samples; they
will be referred to prior sample shipment to ensure all requirements are being met.
The United States Environmental Protection Agency’s Environmental Response Team
(EPA ERT) publishes sampling SOPs for sampling at CERCE A hazardous waste sites.
These SOPs will be followed during the sampling at this site.
QA/QC samples will be collected to assist in the interpretation and validation of the
laboratory analytical results. The QA/QC samples that will be collected during this
characterization sampling program include field duplicates or co-located samples (10
percent of samples). Field duplicate samples will be collected as a check on laboratory
accuracy and precision. One duplicate dust sample will be collected from the bulk dust
and or high-efficiency particulate air (HEPA) filters. The duplicate sample will be placed
67
CITY_21MC100_011979807
NYC-WTC_000448151
OCR can misread numbers and units. Confirm readings against the page image before using them.