Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - January 27, 2006

in the appropriate, clean, laboratory-prepared sample containers and analyzed for the same parameters.

Precision for laboratory and field measurements will be expressed as the relative percent difference between two duplicate determinations. Acceptance criteria for laboratory precision will be those specified in the method or -1-/- 20 percent if not otherwise stated

Data validation will be carried out upon receipt of all laboratory documents. Sample results will be evaluated to assess potential usability issues. The reported results of all QC checks and analytical procedures will evaluated, including holding times, sample preservation techniques, QC sample results, etc. QC samples reviewed to identify potential problems in any of three specific areas: laboratory/instrument performance, sample preparation/matrix effects, and field performance. Laboratory and instrument performance will evaluated by reviewing laboratory blank contamination and instrument calibration data provided by the laboratory. Any unusual matrix effects will be detected by examining the results from matrix spike/matrix spike duplicates, surrogate spike recoveries, and internal standard responses as reported by the laboratory.

Potential problems originating from field sampling work will be evaluated by examining the field duplicate, equipment blank, and trip blank results.

If the evaluation of QC checks indicate laboratory or field problems, then their impact on the data will be reported with the sample results.

Before reporting results, raw data will be reviewed in detail to verify the accuracy of the results reported by the laboratory.

More detailed information is available from individual SOPs for the test of interest or the published method.

Table 10-1 RCRA Waste Characterization Analytical Method, Container, Preservation and Holding Times for selected aqueous and non-aqueous matrices.

Min Container Sample Holding Analyte Method volume Type Freservatio Time (mL) n Acidity EPA 305.1/SM 2310B 1000 P,G Cool, 4 °C 14 days Alkalinity EPA 310.1/SM 2320 B 1000 P,G Cool, 4 °C 14 days Chlorinated EPA 608/ SW 8080 1000 GA Cool, 4 °C 7/14 Pesticides and days PCB’s Corrosivity SW846 Method 9045D or 9040C 500 P,G, Cool, 4 “C immed Flame AA Metals SW 7000/ 500 P HNO3 pH<2 6 mo GFAA Metals SW 7000/ 500 P HNO3 pH<2 6 mo Hexavalent SW7186 500 P,G Cool, 4 °C 24 hr Chromium ICP Metals SW 846 Method 601 OB or 6020 500 P HNO3 pH<2 6 mo

68

CITY_21MC100_011979808

NYC-WTC_000448152

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000448152Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446145

Chain-of-custody form for Environmental Community Air Monitoring Program samples at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000446622

Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

Compare copies and versions →