NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
Corrosivity SW846 Method 9045D or 9040C 500 P, G, Cool, 4 °C immed
Flame AA Metals SW 7000/ ~ 500 P HNO3 pH<2 6 mo
GFAA Metals SW 7000/_________________ 500 P HNO3 pH<2 6 mo
Hexavalent SW 7186 500 P,G Cool, 4 °C 24 hr
Chromium
ICP Metals SW 846 Method 6010B or 6020 500 P HNO3 pH<2 6 mo
Ignitability ASTM D-93-79 or D-93-80 100 g G Cool, 4 °C 28 days
(Flashpoint) orD-3278-78.
Mercury EPA 245.1/SM3112 B/ 500 P HNO3 pH<2 6 mo
SW846 Method 7470A
PAH SW8100 1000 GA Cool, 4 °C 7/40days
PAH SW8310 1000 GA Cool, 4 °C 7/30
days
PCB EPA 608/ SW 8082 1000 GA Cool, 4 "C 7/40
days
pH EPA 150.1/SW 9040 B/ 500 P,G Cool, 4 °C immed
Reactive Cyanide SW9012A, 7.3 1000 P,G Cool, 4 °C 14 days
Reactive Sulfide SW 9030 B/9034 500 P,G zinc acetate, 7 days
NaOH pH>9
TCLP Semivolatile EPA 625/ SW 3510 C/ 8270C 1000 GA Cool, 4 °C 7/40
Organics days
TCLP Volatile EPASW846-1311/8260B 1000 GA Cool, 4 °C 7/40
Organics days
TCLP Pesticide SW846 Method 8081A 1000 GA Cool, 4 °C 7/40
days
TCLP Herbicide SW846 Method 8151A 1000 GA Cool, 4 °C 7/40
days
P = plastic, HOPE G = glass GA= amber glass VOA = 40 mL vial
Preservation should be performed at time of sample collection. Sample bottles with or without preservative
may be obtained by contacting the laboratory. Indication of preservative would be helpful either on the
label or a sample chain of custody (also available from the laboratory). The holding times listed in the table
are the maximum allowable time a sample can be held before analysis and still be in compliance with the
EPA regulations. Sample collection date and time are needed to ensure that holding times are met properly.
10.3 Field Quality Control
This section of the QAPP identifies the QC procedures, checks, samples, and their
respective acceptance limits, that will be used to monitor the quality of various aspects of
the sampling event. Their required analysis frequency, acceptance limits and corrective
actions are also documented in this section of the QAPP.
10.3.1 Field Blanks/Trip Blunks
Field/trip blanks consist of clean sample media. Field/trip blanks accompany samples to
the site and return to the laboratory in the same cooler or shipping container. Field/trip
blanks will be used to ensure that there is no contamination as a result of the
shipment/transportation/on-site storage activities. Field/trip blanks will be collected for
66
CITY_DEP_WORBY_CANNATA_SUBP_000072606
NYC-WTC_000424388