Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

Corrosivity SW846 Method 9045D or 9040C 500 P, G, Cool, 4 °C immed Flame AA Metals SW 7000/ ~ 500 P HNO3 pH<2 6 mo GFAA Metals SW 7000/_________________ 500 P HNO3 pH<2 6 mo Hexavalent SW 7186 500 P,G Cool, 4 °C 24 hr Chromium ICP Metals SW 846 Method 6010B or 6020 500 P HNO3 pH<2 6 mo Ignitability ASTM D-93-79 or D-93-80 100 g G Cool, 4 °C 28 days (Flashpoint) orD-3278-78.

Mercury EPA 245.1/SM3112 B/ 500 P HNO3 pH<2 6 mo SW846 Method 7470A PAH SW8100 1000 GA Cool, 4 °C 7/40days PAH SW8310 1000 GA Cool, 4 °C 7/30 days PCB EPA 608/ SW 8082 1000 GA Cool, 4 "C 7/40 days pH EPA 150.1/SW 9040 B/ 500 P,G Cool, 4 °C immed Reactive Cyanide SW9012A, 7.3 1000 P,G Cool, 4 °C 14 days Reactive Sulfide SW 9030 B/9034 500 P,G zinc acetate, 7 days NaOH pH>9 TCLP Semivolatile EPA 625/ SW 3510 C/ 8270C 1000 GA Cool, 4 °C 7/40 Organics days TCLP Volatile EPASW846-1311/8260B 1000 GA Cool, 4 °C 7/40 Organics days TCLP Pesticide SW846 Method 8081A 1000 GA Cool, 4 °C 7/40 days TCLP Herbicide SW846 Method 8151A 1000 GA Cool, 4 °C 7/40 days P = plastic, HOPE G = glass GA= amber glass VOA = 40 mL vial

Preservation should be performed at time of sample collection. Sample bottles with or without preservative may be obtained by contacting the laboratory. Indication of preservative would be helpful either on the label or a sample chain of custody (also available from the laboratory). The holding times listed in the table are the maximum allowable time a sample can be held before analysis and still be in compliance with the EPA regulations. Sample collection date and time are needed to ensure that holding times are met properly.

10.3 Field Quality Control

This section of the QAPP identifies the QC procedures, checks, samples, and their respective acceptance limits, that will be used to monitor the quality of various aspects of the sampling event. Their required analysis frequency, acceptance limits and corrective actions are also documented in this section of the QAPP.

10.3.1 Field Blanks/Trip Blunks

Field/trip blanks consist of clean sample media. Field/trip blanks accompany samples to the site and return to the laboratory in the same cooler or shipping container. Field/trip blanks will be used to ensure that there is no contamination as a result of the shipment/transportation/on-site storage activities. Field/trip blanks will be collected for

66

CITY_DEP_WORBY_CANNATA_SUBP_0001 01097

NYC-WTC_000427781

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427781Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

Compare copies and versions →