Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

all parameters associated with air samples. Ficld/trip blanks for asbestos and silica will only be analyzed if the asbestos or silica are detected in the associated samples.

10.3.2 Cooler Temperature Blanks

Cooler temperature blanks consist of a sample container filled with non-preserved water (potable or distilled) and are included in all coolers which contain samples which require temperature preservation (PAHs, PCBs, PCDDs/PCDFs). The laboratory uses these temperature blanks to ensure that proper preservation of the samples has been maintained during sample shipment. The temperature of these blanks must be 4 °C ±2° to demonstrate that proper preservation has been maintained. The laboratory records the results of the temperature blanks on the chain-of custody or sample login form immediately upon receipt of the samples at the laboratory, prior to inventory and refrigeration.

10.3.3 Field Duplicates

Field duplicates will be collocated samples. Collocated samples are two samples collected next to each other in the same vertical position. Collocated samples require two separate sample collections at the same location. Field duplicates will be used to assess the sampling and analytical reproducibility. With the exception of total mercury, field duplicates will be submitted at a frequency of once per week per analytical parameter. For total mercury, field duplicates and field spikes will be alternated on a weekly basis.

Field duplicates for waste characterization will be duplicate subsamples. Duplicate subsamples are an additional aliquot of the same sample submitted for the same parameters as the original sample and will be used for aqueous and solid matrices. Duplicate subsamples will be collected by alternately filling sample containers from the source being sampled. Field duplicates will be used to assess the sampling and analytical reproducibility. Field duplicates will be submitted at a frequency of once per 10 samples per matrix per analytical parameter (with the exception of corrosivity and ignitability).

10.3.4 Field Spikes

PCDDs and PAHs Field spikes are clean media used for sampling and pre-spiked with i3Ci2-labeled compounds (similar to the target analytes) and used to evaluate overall accuracy. The media will be spiked in the laboratory, sent out to the field with all sample media, and returned to the laboratory for analysis.

Total Mercury In addition, during the background phase of the program, the accuracy and precision of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the accuracy and precision of the method under actual field sampling condition. Following the background phase, one field spike will be performed every other week.

67

CITY_DEP_WORBY_CANNATA_SUBP_000072607

NYC-WTC_000424389

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000424389Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000427716

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

Compare copies and versions →