Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
Measures to Ensure Field Comparability Comparability is dependent upon the proper
design of the sampling program and will be satisfied by ensuring that the QAPP is
followed, sampling and analytical methodologies are followed, and that proper sampling
and preservation techniques are used.
Measures to Ensure Laboratory Comparability Comparability is dependent on the use
of the selected EPA and NIOSH methods that are appropriate for producing data that may
be compared to the project Action Limits and the reporting of data in standardized units.
8.2.5 Sensitivity
Sensitivity is the ability of the instrument or method to detect the contaminants of
concern at the level of interest.
Quantitation Limits Tables 8-la,b,c outline the required quantitation limits for each
matrix, each analytical parameter and each analyte. These quantitation limits are
significantly below the project Action Limits. In almost all cases, EPA or NIOSH
methodologies were selected with specific requirements or modifications to achieve
quantitation limits that are significantly below the project Action Limits. The laboratories
selected will, at a minimum, meet the project quantitation limits included in Tables 8-
Ia,b,c. Laboratories will need to adjust all quantitation limits based on dilutions, sample
volumes, extract/digestate volumes, and cleanup procedures. In all cases, the adjusted
quantitation limit (or sample quantitation limit) must be below the project Action Limit.
In establishing the required quantitation limits for this program, these factors were
considered in ensuring the project Action Limits would be achieved. Sensitivity will be
maximized by following the EPA and NIOSH methods, utilizing experienced/trained
laboratory personnel, and conducting laboratory audits.
8.2.6 Completeness
Completeness is a measure of the amount of valid data obtained from a measurement
system compared to the amount that was expected to be obtained under normal
conditions. “Normal conditions” are defined as the conditions expected if the sampling
plan was implemented as planned.
Field Completeness Objectives Field completeness is a measure of the amount of (1)
valid measurements obtained from all the measurements taken in the project and (2) valid
samples collected. With the exception of the real-time measurements, the field
completeness objective will be a minimum of 80 percent. This allows for the potential
loss of samples due to sampling problems or media breakage during transport. The
completeness objective for the real-time measurements (e.g., PMio, PM2.5, gaseous
mercury) will be a minimum of 90 percent.