Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
Blanks compounds reanalyze, Contamination
QL and/or qualify
data.
PUF Media 1/batch cleaned No target Reclean batch Accuracy/Bias-
Cleaning compounds > Contamination
Verification QL
Check
Laboratory 1/prep batch Percent Determine Accuracy/Bias
Control Sample recoveries 70- cause of
130% problem
reanalyze
and/or qualify
data.________
Laboratory 1 /prep batch Percent Determine Accuracy/Bias
Control Sample recoveries TO cause of and Precision
Duplicate IS 0% RPD < problem
50 reanalyze
and/or qualify
data.
Dual Column Every sample, %D bet-ween Narrate/Flag Precision
Analysis blank, QC columns < 25 data.
Data NA Field 80%; NA Data
Completeness Laboratory Completeness
Check 95%
Tsb/e 8-5. Measurement Performance Cr/ter/3 Tab/e-FVOOs/PGJFs bv HRGC/HRMS
QC Sample or Frequency Measurement Corrective DQI
Activity Performance Action
Criteria
Field 1/Week *RPD < 40 Assess Precision-
Duplicates when positive laboratory Overall
results for both precision; and
samples are > /or qualify data.
5x QL
*No situation
where one
result is
detected at > 5x
QL and other
result is not
detected
Extraction Every sample, Percent Reanalyze Accuracy/Bias
Standards (pre- blank, QC recoveries 50- and/or qualify
extraction) 120% for tetra- data.
43
CITY_DEP_WORBY_CANNATA_SUBP_000072583
NYC-WTC_000424365
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000424365Source: NYC Law Department, mirrored locally