NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 129 pages

Environmental Community Air Monitoring Plan, Greenwich/Thames

Machine-extracted title · confidence 50%

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

NYC-WTC_000444945–000445073
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

Blanks compounds reanalyze, Contamination QL and/or qualify data.________ PUF Media 1/batch cleaned No target Rcclcan batch Accuracy/Bias- Cleaning compounds > Contamination Verification QL Check Laboratory 1/prep batch Percent Determine Accuracy/Bias Control Sample recoveries 70- cause of 130% problem reanalyze and/or qualify data.________ Laboratory 1/prep batch Percent Determine Accuracy/Bias Control Sample recoveries 70- cause of and Precision Duplicate 130%RPD< problem 50 reanalyze and/or qualify data. Dual Column Every sample, %D between Narrate/Flag Precision Analysis blanh^J2C columns < 25 data.________ Data NA Field 80%; NA Data Completeness Laboratory Completeness Check 95%

Tab/e 8-5. Measurement Performance Criteria Tab/e-PCDDs/PCDFs by HRGC/HRMS QC Sample or Frequency Measurement Corrective DQI Activity Performance Action Criteria Field l/Week *RPD < 40 Assess Precision- Duplicates when positive laboratory Overall results for both precision; and samples are > /or qualify data. 5x QL *No situation where one result is detected at > 5x QL and other result is not detected Extraction Every sample, Percent Reanalyze Accuracy/Bias Standards (pre- blank, QC recoveries 50- and/or qualify extraction) 120% for tetra- data.

43

CITY_21MC100_003240689

NYC-WTC_000444987

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000444987Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

NYC-WTC_000440780

Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →