NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
determined by a non-rcfercnce method utilizing Met One’s E-BAM Mass Monitor, which
is a real-time monitor. BGI samplers will be used to collect PM2.5 via the US EPA
standard reference method (40 CFR Part 50 Appendix L) at one location per day. An
Tisch TE-6070 PM2.5 sampler will be collocated along side the real-time PM2.5 monitors
as a QA check. The Tisch TE-6070 sampler will rotate on a monthly basis through all
real-time PM2.5 monitor locations for the duration of the monitoring program.
10.2.10.1 PM2.5 - Reference Method via BGl Ambient Fine Particulate Sampler
PM2.5 (particles less than 2.5 micrometers in aerodynamic diameter) is collected on 47
mm PTFE membrane media at a volumetric sample rate of 16.67 Lpm after being size
discriminated through two U.S. EPA designed inertial separators. Ambient temperature
and barometric pressure measurements are made at actual sample conditions. A
microprocessor and sophisticated volumetric flow control system arc integrated to
maintain precise sampling parameters while sampling data are continuously logged into
the processor memory. Five minute actual ambient temperature and pressure conditions
with volumetric sample flow rate, filter temperature, and pressure are recorded. Measured
values and identification of flags indicating any anomalies are recovered by the operator
by downloading a sample summary to a laptop or handheld computer.
The sampler specification for the PM2.5 sampler is contained in 40 CFR Part 50 Appendix
L. This document specifies the PM2.5 sampling limits, protocol, and instrument
specifications. The BGI systems perform all of the functions required or recommended in
the instrument specification part of the standard. The inlet has 2.5-micrometer (nominal)
cutpoint. The inlet provides wind speed and direction independent sampling and removes
particles larger than about 2.5 micrometers. Before sampling, the filters are equilibrated
to constant temperature and relative humidity conditions and weighed. After sampling,
the filters are again equilibrated to the constant temperature and humidity conditions and
weighed. The mass concentration is then calculated by dividing the weight of the
particulate captured on the filter by the volume of air (at ambient conditions) that passed
through the sampler. The flow rate is required to be maintained within 5% of 16.67 liters
per minute with a coefficient of variation (a measure of the average short-term variation
in flow in %) of less than 2%. Equipment and supplies utilized with this sampling
approach are as follows:
• Filters - Preweighed 47-mm Teflon® filters. Filters should be stored and
transported in petri dishes.
• Forceps - Non-serrated forceps should be used to handle the 47-mm filters.
• BGI PM2.5 Sampler - A sampling system that meets the requirements of 40
CFR Part 50 Appendix L for the sampling of PM2.5. The BGI sampler
design incorporates a flow-indicating device, a thermometer, a barometer, and a
timing control device into the sample monitor.
• Manometer - A water or oil manometer is used to calibrate the flows of the
samplers.
• Timing/Control Device - A timing device capable of starting and stopping the
sampler to obtain an elapsed run time of 24 hr ±1 hr. The accuracy of the timing
53
CITY_DEP_WORBY_CANNATA_SUBP_000070987
NYC-WTC_000423937
OCR can misread numbers and units. Confirm readings against the page image before using them.