NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - September 29, 2005

• Personal Sampling Pump - The pump used to draw the air through the iodated carbon trap. • Flow Measurement Device - A device such as a rotameter, bubble meter, or gas volume displacement-measuring device such as a “DryCal” flow meter. This device should have a calibration traceable to a NIST certification. • lodated Carbon Trap - The carbon trap provided by the subcontracted laboratory that is used to absorb the mercury from the air that is passed through it.

10.2.9 PMio

PMio will be determined by two separate methods. At each location, PMio will be determined by a non-reference method utilizing Met One’s E-BAM Mass Monitor, which is a real-time monitor. Tisch TE-6070 High Volume MFC PM-10 MFC Monitor Reference Method samplers will be used to collect PMio via the US EPA standard reference method (40 CFR Part 50 Appendix J) at one location each day. A Tisch TE-6070 sampler will be collocated along side the real-time PMio monitors as a QA check. The Tisch TE-6070 sampler will rotate on a monthly basis through all real-time PMio monitor locations for the duration of the monitoring program.

10.2.9.1 PMio-Reference Method via Tisch TE-6070 samplers

Particulate samples whose aerodynamic diameter is < 10 [J will be collected using Tisch TE-6070 samplers operating in the PMio mode. All samples will be collected over an estimated twenty-four hour sampling interval at a prescribed flow rate of 40 sefm. Pre­ weighed Micro-Quartz filter media provided by the subcontracted laboratory will be placed in the TE-6070 sampler prior to the start of each sampling event. The sampler specification for the PMio sampler is contained in 40 CFR Part 50 Appendix J. This document specifies the PMio sampling limits, protocol, and instrument specifications. The TE-6070systQms perform all of the functions required or recommended in the instrument specification part of the standard.

10.2.9.2 PMio - Continuous Monitoring of PMio via Met One E-BAM Samplers

The monitors selected to continuously measure PMio are beta-attenuation monitors manufactured by Met One Instruments, Inc. (Met One). The E-BAM monitors will be equipped with particle size selective inlets. The design of the inlets is such that particles larger than the desired size range will be removed from the air flow at the prescribed air flow rate. The units will be equipped with an inlet head to separate PMio. Sampling flow rate is critical to maintain the proper particle size cut points of the inlets. Flow rates are maintained at 16.7 liters per minute in the E-BAM monitors using an integral flow meter, pressure sensor, and ambient temperature sensor on board each monitor.

10.2.10 PM2.5

PM2.5 will be determined by two separate methods. At each location, PM2.5 will be

52

CITY_DEP_WORBY_CANNATA_SUBP_000070986

NYC-WTC_000423936

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423936Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451195

QA plan for environmental air monitoring and waste management at NYC sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →