static electricity is evident (c.g., filter not releasing easily from the forceps or it attracts
the balance pan), the filter should be passed over an anti-static radiation source. Filters
are assembled in the filter cassettes and the cassettes closed firmly by placing a plug at
each opening of the cassette to prevent leakage around the filter. For at least 2 hours prior
to sampling, the filters are equilibrated in either an environmentally controlled weighing
area or chamber. Pump flow rates of each personal sampling pump, with a representative
sampler in line and cyclone grit pot in place, will be measured before and after sample
collection. The pump will be run for 10 minutes prior to checking the flow rate. A
suitable rotameter (or bubble meter) will be connected to the filter inlet, the flow screw
adjusted to the desired sampling value, and the flow rate observed on the rotameter (or
bubble meter) will be verified as constant for a minimum of 20 seconds. Flow rates will
be recorded on Field Sampling Data Sheets or an equivalent field logbook. The cyclone’s
grit cap is removed prior to use and the interior inspected. If the inside is visibly scored,
replace the cyclone because the dust separation characteristics may be altered. Clean
the interior of the cyclone to prevent re-entrainment of large particles. Assemble the
sampler head checking for alignment of the filter holder and cyclone in the sampling head
to prevent leakage. Care must be taken to prevent the sampler assembly from inverting at
any time. Immediately prior to collecting a sample, the sampler will be fastened to a
location (i.e., on a tripod) near the individual’s breathing zone, the top cover of the filter
cassette cowl extension (“open face”) will be removed and positioned “face down” in the
sampler. The joint between the extender and monitor body will be wrapped with tape to
hold the cassette securely in place and to provide a surface to identify the cassette. By
inserting a pin through the hole near the display screen, the elapsed time indicator is reset
prior to sampling. At the end of the sampling period, the top cover and small end caps are
replaced. Samples are transported upright to the laboratory in a rigid container with
packing material to prevent jostling or damage. To avoid electrostatic forces from
causing fiber loss from the sampling filter, untreated polystyrene foam will not be used
for any of the shipping container materials. Collection of a site-specific dust sample will
be performed as discussed in Section 8.2.2. This sample needs to be double-bagged prior
to shipment to avoid any potential cross-contamination. Equipment and supplies utilized
with this sampling approach are as follows:
• Personal Monitor and Sampling Pump 0.5 to 3 1pm • Battery Pack - Nickel metal
hydride battery pack (or equivalent), fitted with a belt clip, compatible with the
personal sampling pump.
• Filters - Polyvinyl filter (or equivalent hydrophobic membrane filter) supported
by a cassette filter holder, 5.0-|Jm pore size, suitable for connection with the
personal monitoring pump system.
• Cyclone - SKC Inc. aluminum cyclone (or equivalent) • Medium Flow Rotometer
- 0.4 to 4.0 1pm • High Flow Rotometer - 2.0 to 20.0 1pm • Forceps - Nylon, used
when handling the filters