NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
validation will be performed on a weekly basis followed by a monthly basis
thereafter. Completeness checks will be administered on all data to determine whether
deliverables specified in the QAPP are present. The reviewer will determine whether
all required items are present and will request copies of missing deliverables.
Field notes will be reviewed in conjunction with the laboratory data to allow for an
overall assessment. Upon completion of the validation, a report will be prepared
summarizing the elements reviewed. Validated data will be used to generate tables.
Potential validation qualifiers are as follows:
U - Not detected at the specified quantitation/detection limit
UJ - Estimated nondetect
J - Estimated value
R - Unusable data point
N - Presumptively present
16.2 Data Usability
The purpose of this section is to indicate the methods by which it will be ensured that
the validated laboratory data collected for this investigation are consistent with the
project quality objectives established for the project, to ensure the quality of data was
sufficient for its intended use, and to identify trends, relationships, and anomalies in
the data. Conclusions based on the data, limitations on the use of the data, and the
determination if data gaps exist will be included in the Data Validation memoranda.
This will be performed on a per sample batch basis.
16.2.1 Precision
The RPD between the LCS and LCS duplicate or sample and sample duplicate, is
calculated to compare to precision objectives. LCS/LCS duplicates and laboratory
duplicates will be used to assess analytical precision and the field duplicates will be
used to assess project precision. The RPD will be calculated according to the
following formula:
The impact of analytical imprecision, project imprecision, and overall imprecision
(when both analytical and project precision tests show problems) on data usability
will be assessed. If the precision results yield data which arc not usable, the Data
Validation memoranda will identify how this problem will be resolved.
16.2.2 Accuracy
If field or laboratory contamination exists, the impact on the data will be evaluated
during the data usability assessment. The direction of bias for contamination will be
identified. Accuracy is assessed by determining percent recoveries (%Rs) for
surrogate/intemal standard compounds added to each field and QC sample to be
100
CITY_DEP_WORBY_CANNATA_SUBP_000071034
NYC-WTC_000423984
OCR can misread numbers and units. Confirm readings against the page image before using them.