Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - September 29, 2005

validation will be performed on a weekly basis followed by a monthly basis thereafter. Completeness checks will be administered on all data to determine whether deliverables specified in the QAPP are present. The reviewer will determine whether all required items are present and will request copies of missing deliverables. Field notes will be reviewed in conjunction with the laboratory data to allow for an overall assessment. Upon completion of the validation, a report will be prepared summarizing the elements reviewed. Validated data will be used to generate tables. Potential validation qualifiers are as follows: U - Not detected at the specified quantitation/detection limit UJ - Estimated nondetect J - Estimated value R - Unusable data point N - Presumptively present

16.2 Data Usability

The purpose of this section is to indicate the methods by which it will be ensured that the validated laboratory data collected for this investigation are consistent with the project quality objectives established for the project, to ensure the quality of data was sufficient for its intended use, and to identify trends, relationships, and anomalies in the data. Conclusions based on the data, limitations on the use of the data, and the determination if data gaps exist will be included in the Data Validation memoranda. This will be performed on a per sample batch basis.

16.2.1 Precision

The RPD between the LCS and LCS duplicate or sample and sample duplicate, is calculated to compare to precision objectives. LCS/LCS duplicates and laboratory duplicates will be used to assess analytical precision and the field duplicates will be used to assess project precision. The RPD will be calculated according to the following formula:

Tffwffpif is

The impact of analytical imprecision, project imprecision, and overall imprecision (when both analytical and project precision tests show problems) on data usability will be assessed. If the precision results yield data which arc not usable, the Data Validation memoranda will identify how this problem will be resolved.

16.2.2 Accuracy

If field or laboratory contamination exists, the impact on the data will be evaluated during the data usability assessment. The direction of bias for contamination will be identified. Accuracy is assessed by determining percent recoveries (%Rs) for surrogate/intemal standard compounds added to each field and QC sample to be

100

CITY_DEP_WORBY_CANNATA_SUBP_0001 01751

NYC-WTC_000427999

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427999Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000423885

Quality Assurance Project Plan for environmental air monitoring and waste management at Greenwich and Thames sites; Sept 30, 2005.

Similar indexed content

NYC-WTC_000451195

QA plan for environmental air monitoring and waste management at NYC sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →