NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - February 1, 2006
• Correct interpretation of data (e.g., mass spectra, chromatographic
interferences, etc.),
• Correctness of numerical input when computer programs are used (checked
randomly) and numerical correctness of calculations and formulas (checked
randomly),
• Acceptability of QC data,
• Documentation that instruments were operating according to method
specifications (calibrations, performance checks, etc.),
• Documentation of dilution factors, standard concentrations, etc.,
• Sample holding time assessment,
• Nonconforming events have been addressed by corrective action as defined on
a nonconformance memo.
A third-level review will be performed by the Laboratory Project Manager before
results are submitted to the client. This review serves to verify the completeness of
the data report and to ensure that project requirements are met for the analyses
performed. The items to be reviewed will include:
• Results are present for every sample in the analytical batch or reporting group,
• Every parameter or target compound requested is reported,
• The correct units and correct number of significant figures are utilized,
• All nonconformances, including holding time violations, and data evaluation
statements that impact the data quality are accompanied by clearly expressed
comments from the laboratory,
• The final report is legible, contains all the supporting documentation required
by the project, and is in either the standard foraiat or in the client-required
format.
A narrative to accompany the final report will be finalized by the Laboratory Project
Manager. This narrative will include relevant comments, including data anomalies
and non-conformances.
16.1.3.2 Independent Review
An independent review of fixed laboratory data will be performed by AIRTEK in
order to determine the quality of the analytical data. Data will be validated according
to USEPA Contract Laboratory Program National Functional Guidelines for
Organic Data Review fEPA-540/R-99- 008), October 1999, USEPA Contract
Laboratory Program National Functional Guidelines for Inorganic Data Review
(EPA 540-R-04-004), October 2004, and USEPA Contract Laboratory Program
National Functional Guidelines for Chlorinated Dioxin/Furan Data Review (EPA-
540- R-02-003), August 2002, which will be modified as necessary to include method
specific criteria, as detailed throughout this QAPP and in the EPA and NIOSH
methods. Data will also be validated and qualified according to the following
121
CITY_21MC100_0 03239974
NYC-WTC_000446742
OCR can misread numbers and units. Confirm readings against the page image before using them.