Rooftop bulk/air sampling summary, 2002

Machine-extracted title · confidence 42%

Detailed chain-of-custody table for bulk and air samples with positive asbestos readings.

NYC-WTC_000421430–000421506
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

02/20/2002 0fl:34 FAX 1^075

Summaiy ofAsbestos Sainpling Results Page 2 of 3 Ach^ess: /(to John Street Date sampled: Dec 3, 200J

Results of Phase Contrast Microscopy (PCM) testing ofaii &t 100 John Street, Dec 3, 2QQ1 Area Sampled_________ Outside Cemmon Residence 1 Residence 2

Sample Numbers A-0-27 A-C-27 A-Rl-27 A.R2-27 Concentrauor. of Fibers (Pec)’ at <0.001 <0.001 <0.001 <0.001 100 John Street Concentration of Fibers (Fee) in <0,001 to .001 <0,001 to 0.002 <0.001 to 0.003 <0.001 to 0,003 comparison locations NYC Re-occupancy Standard 0.01 0.01 0,01 0,01 (Fee)** ____ * f/cc is fibers in each cubic centimeter (oc) of air. This is calculated &om the number of fibers seen on the air filter and the volume of air psiUed fiuough the filter measured la cubic centimeters of air. ** New York City Departmem of EnviroamentaS Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chater 1)

ASBESTOS DUST TEST RESULTS

In general, the dust and debris samples were examined by two different laboratory methods for asbestos fibers. Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM is used to define asbestos containing material in dust and debris. A material is considered to be asbestos containing material if it contains more than 1% asbestos using the PLM method. The PLM method only counts the larger asbestos fibers. Therefore, if results by PLM were not greater than 1% asbestos, ths sample was then analyzed by the TEM method that does count the smaller fibers. However, lEM analysis is not used for regulatory purposes for dust samples.

No asbestos fibers were found in the dust samples by the PLM laboratory method. Further analysis by the TEM method detected asbestos at levels of less than 1% in the dust outside, the common area, and one of the residences.

Fibrous materials in dust found by FLM analysis: Polarized Light Microscopy identihes asbestos fibers by shape and optical ch^acteristics. Other fibers such as fabric (synthetics), paper (cellulose) and fiberg'ass may be identified in the analysis. The laboratory analyst counts the fibers present to give an estimate of fiber content. PLM is used for regulatory purposes for dust samples.

’^5' 10984

CITY_DEP_WORBY_CANNATA_SUBP_000027759

NYC-WTC_000421505

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000421505Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →