Asbestos air test results, 100 [name], Dec 2001

Machine-extracted title · confidence 25%

Summary of asbestos air testing results for 100 [name], including multiple locations and dust sampling.

NYC-WTC_000275422–000275424
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Summary ofAsbestos Sampling Results Page 2 of 3 Address: JOO John Street Date sampled: Dec 3, 2001

Results of Phase Contrast Microscopy (PCM) testing of air at 100 John Street, Dec. 3, 2001 Area Sampled Outside Common Residence 1 Residence 2

Sample Numbers A-0-27 A-C-27 A-Rl-27 A-R2-27 Concentration of Fibers (fee)* at <0.001 <0.001 <0.001 <0.001 100 John Street

Concentration of Fibers (fee) in <0.001 to .001 <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.003 comparison locations NYC Re-occupancy Standard 0.01 0.01 0.01 0.01 (f/cc)** * fZee is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters of air. ** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chapter 1)

ASBESTOS DUST TEST RESULTS

In general, the dust and debris samples were examined by two different laboratory methods for asbestos fibers, Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM is used to define asbestos containing material in dust and debris. A material is considered to be asbestos containing material if it contains more than 1% asbestos using the PLM method. The PLM method only counts the larger asbestos fibers. Therefore, if results by PLM were not greater than 1% asbestos, the sample was then analyzed by the TEM method that does count the smaller fibers. However, TEM analysis is not used for regulatory purposes for dust samples.

No asbestos fibers were found in the dust samples by the PLM laboratory method. Further analysis by the TEM method detected asbestos at levels of less than 1% in the dust outside, the common area, and one of the residences.

Fibrous materials in dust found by PLM analysis: Polarized Light Microscopy identifies asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics), paper (cellulose) and fiberglass may be identified in the analysis. The laboratory analyst counts the fibers present to give an estimate of fiber content. PLM is used for regulatory purposes for dust samples.

CITY_21MC100_004204843

NYC-WTC_000275423

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275423Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →