Rooftop bulk/air sampling summary, 2002

Machine-extracted title · confidence 42%

Detailed chain-of-custody table for bulk and air samples with positive asbestos readings.

NYC-WTC_000421430–000421506
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

1^030 02/20/2002 00:09 FAS DEC. 4.2001 li;37An JLC EWlRONMENTflU NO.133 P.a<7

The Renaissance JLC Project# 01-2226 December 4. 2001 page 2 Air Sampling Analysis and Precedure

introduction Air sampling is defined as the process of measuring the filter content of a known volume of air entrained on a fitter membrane over a specified period of time. Each sample is cross-referenced by field designation and a JLC lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation tsk®$ place within an HE^A filter clean bench to avoid any possible contamination.

Methodology Test procedures for these samples conform to the National Institute of Occupational Safety and Hearth (NIOSH) standards.

Air sampling was conducted at a level approximating the breathing zone of persons anticipated to be present in the area during normal oparstions, Samples collscted should represent the area's typical airborne fiber concentration.

All samples were collected on fully exposed 25 millEmeter, 0.8 micrometer (pm) ceEluicse ester membrane air sampling cassettes with conductive cowl.

Anajyhcal Procedures oA section of the filter approximating twenty-five percent of the total filter was removed and placed on a pre-cleaned microscope slide and then exposed to approximately 253 microliter (pl) of acetone vapor. A single 3.0 - 3.5 pl drop of triacetin was applied end a clean #1,5 cover slip was placed upon toe filter. The prepared slide was then heated on a slide heater until darlty allowed analysis to be conducted.

Analysis was accomplished utilizing a Phase Contrast Microscope in accordance with MOSH 7400 method, counting rule ‘’A?

Phase Contrast Microscopy JLC Environmental's laboratory uses an Olympus BH-PC Phase Contrast Microacscpe, (PCM) equipped with a Walton-Beckett Graticule. Samples were analyzed by first dissolving toe filter through a chemical process (described above) and then counting the fibers with PCM at 400x magnification. Phase contrast increases th© light contrast between the object and the background, thus enhancing the mlcrosccpist's ability to see fibers. Norm ally, 100 microscopic fields or 100 fibers are counted, whichever occurs first,

Analytical Reauits The "Summary of Analytical Results" represents the results of the analysis of the samples, The PCM limit of reliable quahtification is less than 0.01 fibers/cubic centimeter (f/cc) of air if final tests do not meet these requirements, the entire work site must be re-cleaned and re-tested.

5 o 10939

CITY_DEP_WORBY_CANNATA_SUBP_000027714

NYC-WTC_000421460

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000421460Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →