NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 77 pages

Bulk sample/custody form for asbestos PLM tests

Machine-extracted title · confidence 45%

Bulk sample tracking form including PLM methods and negative/positive counts.

NYC-WTC_000417978–000418054
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document - h. Am

02/20/2002 09:13 FAX ig|036

The Renaissance JLC Project # 01-2226 December 5, 2001 page 2 Air Sampling Anaivsig and Procedure

Introduction Air sampling is defined as the process of measuring the filter content of a known volume of air entrained on a filter membrane over a specified period of time. Each sample is cross-referenced by field designation and a JLC lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation takes place within an HE PA filter clean bench to avoid any possible contamination.

Methodology Test procedures for these samples conform to the National Institute of Occupational Safety and Health (MOSH) standards.

Air sampling was conducted at a Seve! approximating Ute breathing zone of persons anticipated to be present In the area during normal operations Samples collected should represent the area's typicai airborne fiber concentration.

All samples were collected on fully exposed 25 millimeter, 0.8 micro meter (pm) cellulose ester membrane air sampling cassettes with conductive cowl.

Analytical Procedures A section of the filter approximating twenty-five percent of the total filter was removed and placed on a pre-cleaned microscope slide and then exposed to approximately 250 microliter (pi) of acetone vapor. A single 3.0 - 3.5 pl drop of triacetin was applied and a clean #1.5 cover slip was placed upon the filter. The prepared slide was then heated on a slide heater until clarity allowed analysis to be conducted.

Analysis was accomplished utilizing a Phase Contrast Microscope in accordance with MOSH 7400 method, counting rule "A."

Phase Contrast Microscopy JLC Environmental's laboratory uses an Olympus BH-PC Phase Contrast Microscope, (PCM) . I

equipped with a Walton-Beckett Graticule. Samples were analyzed by first dissolving the filter 1

through a chemical process (described above) and then counting the fibers with PCM at 400x magnification. Phase contrast increases the light contrast between the object and the background, thus enhancing the microscopist's ability to see fibers. Normally, 100 microscopic fields or 100 fibers are counted, whichever occurs first.

Analytical Results The "Summary of Analytical Results" represents the results of the analysis of the samples. The PCM limit of reliable quantification is less than 0.01 fibers/cubic centimeter (f/oc) of air. If final tests do not meet tiiese requirements, the entire work site must be re-cleaned and re-tested. 1

10945 CITY_21MC100_011066673

NYC-WTC_000418014

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418014Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →