Chain-of-custody: 21 West Street air samples, Feb 2002

Machine-extracted title · confidence 33%

Chain-of-custody for air monitoring samples collected after 2001 event at 21 West Street; references lab results and contractor contacts.

NYC-WTC_000418335–000418419
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

'7^-^2002'THU 11:1& AN CLOSINGS S ROSE FAX NO. 212 2W 6724 P. 37/42

i ‘ ’ ' '’ , ; , . Rose Associates h JLC Project #01-2089 J September IB, 2001 page 2 Air Saifsplina Analysis and Procedure

Introduction Air sampling is dsfined as the process of measuring the filter content of a known volume of air eplrairied on a filter membrane over a specified period of time. Each sample is cross-referenced by , field dealgnation and a JLC lab internal code to ensure proper, consistent handling through a chain ; of custady, Sample preparation takes place within an HEPA filter clean bench to avoid any poesible J contamination.

, Methodology ■ ' T^at procedures for these samples conform to the National Institute of Oncupational Safety and ,r Health (NIOSH) standards. ' I

Air sampling was conducted at a level approximating the breathing zone of persons gnticipstsd to he present in the area during normal operations. Samples collected should represent the area's ; , topical nidiotnA fiber concentration,

All eamploa were collected on fully exposed 20 millimoter, O.S mlwonietwr (pm) cellulose ester membrane air sampling cassettes with conductive cowl. 'i

Analytical Procedures 'i A soction of the filter approximating twenty-five percent of Itie total filter was removed and placed on a pre- clesrcd microscope slide and then exposed to approximately 250 mscrcliter (pl) of acetone vapor. A singie 3.0 - 3.5 pl drop of triacetln was applied and a clean #1.5 cover slip was placed upon the filter. The prepared slide was then heated on a slide heater until cinrib/ allowed analysis to I '■I', ba conducted.

, Analysis was? accomplished utilizing a Phase Contrast Microscope In accordance with NIOSH 7400 1 1 method, counting rule ”A."

Phase Contrast Microscopy JLC Environmental's laboratory uses an Olympus BH~PC Phase Contrast Microscope, (PCM) •is equipped with s Walton-Beckett Graticule. Samples were analyzed by first dissolving the Altar through a chemical process (described above) and then counting ths fibers with PCM at 400x msignificatlon. Phase contrast increases the light contrast between the object and the background, thus enhancing the microscopist's ability to occ fibers. Norir.aliy, 100 microscopic fields or 100 Rbers are counted, whichever occurs first,

y 7 Analytical Results ly '", The 'LSummary of Analytical Results’’ represents the reeuits of the analysis of the samples. The PCM limit of reliable quantificaticn Is less than 0.01 fibersZcubsc centimeter (fZee) of air. If final tests •' do not meet these leMuirementa, the entire work site must be re-cleaned and re-tested.

1 05036 CITY_21MC100_011970979

NYC-WTC_000418371

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418371Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →