NYC 9/11 Public Portal Document
Ji I »frv3>jaGi.i jW-
.1
ambient group me. national hl a DOU ARTERS
ICIO indoor environmenteS quality surveys
55 WEST 39™ STREET
121K FLOOR.
Water treatment consulting KleW TOKXy NET? 'TOKK TOOlS
/-W''
Asbestos & lead field services reu C2IZ) 463-7312
Regulatory compliance prograrri Er\X: f212) 463-9397
Air, water & soil analytical laboratories W£S: WWWJIMB38NTGROUP.COM
September 17,2001
Mr. Eliot Zuckerman
Cushman & Wakefield
a/a/f Mercantile Exchange
One North End Avenue
New York, New York 10282
Re: One North End Avenue
Ambient Project #211338
Dear Mr. Zuckermen:
The following is a summary of the indoor environmental quality survey that Ambient Group,
Inc. performed on September 14^\ 2001 at the above referenced location. The survey included
sampling for levels of background gaseous parameters, airborne dust characterization and air
sample collection for TEM analysis, as well as absence/presence of asbestos in settled dust.
Analysis of all indoor gaseous air quality parameters, which included carbon dioxide, carbon
monoxide, and total volatile organic compounds groups I and group U revealed that all indoor
readings were below OSHA, ACGIH, ASHRAE and other recommended industry guidelines
and/or regulations.
Seven (7) air samples were collected from various locations on floors 3, 7, 10,11, 13, 15 and
lobby analyzed by transmission electron microscopy (TEM)- for asbestos structures. The
results of the analysis indicated that airborne asbestos levels at the time of testing were less
than the analytical sensitivity of the instrument, as well as well below the EPA standard of 70
structures/mm^ and other recommended industry guidelines and/or regulations.
Seven (7) air samples were collected from various locations on floors 3, 7, 10, 11, 13, 15, and
lobby and analyzed for dust characterization. The samples were composed primarily of fungal
spores, skin fiagments, gravel road dust, carbon particles, and cement dust. Although the
concentrations of carbon particles, cement dust, skin firagments and fungal spores were
slightly elevated, the levels detected should not pose any adverse health concerns to the
building occupants.
OLES cove, t^Y MIAMI. FL CHICA<50» IL ORANGE, CA
•516 609^009 jof 36q-oioi 31 z 527-5516 714 7.82-2525
00593
CITY_21MC100_008878660
NYC-WTC_000417447
OCR can misread numbers and units. Confirm readings against the page image before using them.