NYC 9/11 Public Portal Document
-•nuv-utruf rKi uoiJJ rn nritJiCMi uKuur imu MU. ZIZ /BB tbqu r. uz
■>
ambient group he. NATt OS!A b ) J J ..U 1J.JI lA H, ri'!(
55 Av til V)!ll .SI’RWir
IneJoDt environmtitwl qLMlity surveys
(/I.UIWH
Waiar traaUtiwit tureultitig Ml IB VnilK, Nl Av v'tJRK RkVS
AsbWtas & lead field servlcw Till ; .fej.yKll
Regulatory compliance pro^raitis
Air, water ft wtl analytical labnratorief wiiu; ww w. UM It! EN1 Ilitti irn niM
November 9,2001
Mr. Elliot Zuckerman
Cushman & Wakefield
. a/a/f Mercantile Exchange
One North End Avenue
New York, New York 10282
Ke; One North End Avenue
Ambient Project # 211338
Deaf Mr, Zuckerman:
The following is a summary of the indoor environmental quality survey that Ambient Group, Inc.
performed on'November 6, 2001 at the above referenced location. The survey included sampling
for airborne metals, polynuclear aromatic hydrocarbons and airborne asbestos structures by TEM,
Four (4) air samples were collected from various locations on floors 3, 7. 12 and from outside the
building and an^yzed by transmission electron mitrostopy (TEM) for asbestos structures. The
results of the analysis indicated that airborne asbestos levels inside and outside the building at the
time of testing were less than the analytical sensitivity of the instrument, which is well below the
EPA standard of 70 structures/mm^ as well as other recommended industry guidelines and/or
regulations.
Four (4) air samples were collected floors 3, 7, 12 and outside the building and analyzed
for polynuclear aromatic hydrocarbons in air. Analysis of all four (4) samples collected
revealed that the levels of the individual compounds were below the OSHA Permissible
Exposure Limits and NIOSH KEL guidelines.
Four (4) air samples were collected from floors 3, 7,12 and outside the building and analyzed
.&r metals in air. All measured meftals were within their respective OSHA Permissible
Exposure Limits.
GtJ.!* fOVF, NV .MIAMI, Ft. ta4<f:Ar:n. tl. (IUANC.I., <74
51^. (X7Q-Otlfty ^7-51 J* 714
11/og/Dl ERI 17:37 [TX/RX NO S445J 00480
CITY_21MC100_008878157
NYC-WTC_000231011
OCR can misread numbers and units. Confirm readings against the page image before using them.