NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

NYC-WTC_000409493

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000409493–000409494
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ENVfi I N C O R P TAL TED The First Choice for Environmental Testing & Consulting

October 17. 2001

Gateway Plaza Management Corporation 375 South End Avenue New York, New York 10280

Subject; Ga tew ay Plaza Building #300

Gentlemen:

ALC Environmental Incorporated (ALC) has been retained to perform bulk sampling, visual assessments & air monitoring according to the EPA Protocol to determine the presence of asbestos at the above referenced project. Every apartment in the building was assessed by our inspectors for dust and debris. Any area where visible dust and debris was found, ALC’s inspectors took a bulk sample, which was then sent to a third party independent laboratory for analysis. In most cases there was insufficient debris to sample and a visual assessment only was performed. Additionally, air sampling was performed using TEM Methodology on every floor in the building.

Twelve (12) initial background air samples were collected and analyzed via phase contrast microscopy (PCM) at building 300. Seven (7) samples were analyzed via Transmission Electron Microscopy (TEM). After analysis via TEM, ail were below the permissible limits.

Based on EPA Guidelines, we collected six (6) bulk samples and analyzed them via Polarized Light Microscopy (PLM) Methodology. Zero (0) were found to be above the regulatory limits.

ALC then collected air samples on every floor in the building. The air sampling and analysis was done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE H AHERA/ASMARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.

Thirty (30) air samples were collected and analyzed via TEM Methodology. The results indicated that the living areas achieved the acceptance criteria below <70 structures per mm2 set by the above regulations.

115 West 30th .Street • 11th Floor • New York. New York 10001 • 212 279.1001 • 888.466.3620 • Fax: 212.279.6747

Home tllliee: The Bellevue • Sune 600 • 200 S Broad Street • Philadelphia, P.3 16102 • 215 7 32.0466 » 888,789.8378 • Fax: 215.732.9559

ivu 11 .ALt'Envii onmentiil.i.oni

CONFIDENTIAL, CITY_2IMCl00_003385298 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000409493

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000409493Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342648

ALC subcontract: bulk sampling, visual assessments, and air monitoring for Building #300.

Similar indexed content

Compare copies and versions →