Bulk sampling update, Building 600, Dec 2001

Machine-extracted title · confidence 49%

Bulk sampling and air monitoring update for Building 600; background air samples noted.

NYC-WTC_000409424–000409425
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Hi ENVIRON. INCOnPORA'ED TAL The First Choice for Environmental Testing & Consulting

December 19, 2001

Gate'.vay Plaza Management Corporation 375 South End Avenue New York, New York 10280 Via Facsimile

Subject: Gateway Plaza Building #600

Gentlemen:

ALC Environmental Incorporated (ALC) has been retained to perform bulk sampling, visual assessments & air monitoring according to the EPA Protocol to determine the presence of asbestos at the above referenced project. Every apartment in rhe building was assessed by our inspectors for dust and debris. Any area where visible dust and debris was found, ALC’s inspectors took a bulk sample, which was then sent to a third party independent laboratory for analysis. In most cases there was insufficient debns to sample and a visual assessment only was performed. Additionally, air sampling was performed using TEM Methodology on every floor in the building.

Thirty (30) initial background air samples were collected and analyzed at building 600. Thirty (30) samples were analyzed via phase contrast microscopy (PCM) and seventeen (17) were re-analyzed via transmission electron microscopy (TEM). Ten (10) bulk samples were collected and analyzed via Polarized Light Microscopy (PLM) and via Transmission Electron Microscopy (TEM). All were below the permissible limits.

Based on EPA Guidelines, we collected one hundred fifty-three (153) bulk samples and analyzed them via Polarized Light Microscopy (PLM) Methodology. Upon the laboratories recommendation one hundred and fourteen (114) samples were analyzed via Transmission Electron Microscopy (TEM) to confirm the findings. Twelve (12) samples collected from eleven (11) apartments were found to be slightly above the regulatory limits of 1%. However, certified asbestos abatement contractors hired independently by the owner, were used to clean those specific apartments found to be in question and the areas were cleared by ALC via TEM sampling. All air samples were found to be well below the permissible limits and the tenants where this cleaning took place have been notified of the clearance.

ALC then collected air samples on every floor in the building. The air sampling and analysis was done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE H AHERA/ASHARA (40 CFR PART 763) Asbestos

115 West 30th Street • 11th Floor • New York, New York 10001 • 212.279.1001 • 888.466.3620 • Fax: 212.279.6747 Home Office; The Bellevue • Sune 600 • 200 S. Broad Street • Philadelphia. PA 19102 • 215,732.9499 • 888.789,8378 • Fax; 215,732,9559 WWW ALCEnvironmerital.com

CONFIDENTIAL, CITY_2IMCl00_003385194 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000409424

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000409424Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →