WTC Indoor Air Monitoring - Sampling and Analytical Procedures
Analytical
Media Sa-Tpling Points Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed
Parameters
"This test method does not describe procedures or techniques
required to evaluate the safety or habitability of buildings with
Asbestos Microvac ASTM 5755-95 asbestos-containing materials, or compliance with federal, state, or ASTM 5755-95
' ' z-z CJ* “
local regulations or statutes. It is the user's responsibility to make
1 these determinations." (Section 5.1.1 of method 5755-95)
k\ -■
A.-,
Lead Microvac ASTM 5755-95** NIOSH 7300
Carpets, fabric furniture or
Porous Soft After speaking with several people in HQ and RTP, it does not
drapery "i areas of activity Still checking on methods. Reached
surfaces appear there are standardized methods for the collection of these To be determined once the sampling method (if
(living reams, family rooms) Dioxins out to RTP and HQ. Waiting for
parameters, rather many of the methods being used today are any) has be selected
additional information
research and development procedures.
PAHs
Silica
See the comment for asbestos. Samples will be combined with the
MMVF Microvac ASTM 5755-95 EMSL MSD.0300
asbestos sampling.
"This test method does not describe procedures or techniques
required to evaluate the safety or habitability of buildings with
Wipe ASTM D 6480-99 or ASTM D 6480-99 (wipe) or
Asbestos asbestos-containing materials, or com:)tiance with federal, state, or
Microvac ASTM 5755-95 ASTM 5755-95 (microvac)
local regulations or statutes. It is the user's responsibility to make
these determinations." (Section 5.1.1 of method 5755-95)
Horizontal surfaces of
Non-porous tables or counters and
Lead NIOSH 9100 None known, wipe sampling has been legally defended. SW-846 601 OB
Hard baretioors, ceilings and
surfaces walls io areas of activity Dioxins ASTM D 6661-01 ASTM 6661-01/SW-846 8290
(living rnntns, family rooms)
PAHs ASTM D 6661-01 ASTM 6661-01/SW-846 8270C
Silica See comment for silica above. See comment for silica above. See comment tor silica above.
Wipe ASTM D 6480-99 or Same as asbestos microvac. Samples will be combined with the
MMVF EMSL MSD.0300
Microvac ASTM 5755-95 asbestos sampling.
Air pump operated at lOL/min for 8 hours to achieve the PIC PCM NIOSH 7400 followed by TEM AHERA
Asbestos NIOSH 7400
wkgroup detection limits method.
Air pump operated at lOL/min for 8 hours to achieve the PIC
Lead NIOSH 7300 SW-846 601 OB
Areas of known activity wkgroup detection limits
Indoor Air
(living morns, family rooms) Air pump operated at 2.5L/min for 8 hours to achieve the PIC
Silica NIOSH 7500 NIOSH 7500 (XRD)
wkgroup detection limits
Assumed that it behaves the same as asbestos, samples will be
MMVF NIOSH 7400 EMSL MSD.0300
combined with the asbestos sampling.
NOTE: All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh the
sample wipe or cassette prior to performing the analysis.
** This method is for asbestos and is being modified for the collection of lead dust. Modification - to use the filter specified for method NIOSH 7300