NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Asbestos and lead sampling notes

Machine-extracted title · confidence 28%

Laboratory summary page for fabric/furniture sampling and composite locations.

NYC-WTC_000407866–000407869
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

[Andrew Yasl],a(i^WTCindra(|rsampR1.)^ alyt PfOCbjCiorOS F jr Bdukyr uun J ell id Pilot CleHII tip Slihdics* Analytical Media Sampling Points Sampling Method Proposed Description Parameters Settled Dust Carpets, fabric furniture or This is a micro vacuuming method. Three co-located samples will be Porous Soft drapery in areas of activity Asbestos ASTM D 5755-95 collected from each location. surfaces (living rooms, family rooms) This is a micro vacuuming method. Three co-located samples will be Lead ASTM E 1973-99 Settled Dust collected from each location. Non-porous floors, ceilings and wails in Asbestos ASTM D 6480-99 Wipe Samples Hard jj-QQg 3ctivity (jiving Lead HUD Appendix 13.1 Wipe Samples Dioxins ASTM D 6661-01 Wipe Samples PAHs ASTM D 6661-01 Wipe Samples Total Dust HUDAppendix13.1** Wipe Sample collected at one location per unit. Silica, calcite, HUD Appendix 13.1** Wipe Samples. All parameters will be collected on one wipe. gypsum MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling.

Areas of known activity Air pump operated at lOUmin for 8 hours to achieve the COPC Indoor Air Asbestos NIOSH 7400 (living rooms, family rooms) wkgroup Practical Quantitation Limit (PQL) Air pump operated at lOL/min for 8 hours to achieve the COPC Lead NIOSH 7300 wkgroup PQL

kir pump operated at 2L/min for 8 hours. Pilot Clean-up study only for PAHs NIOSH 5515 worst case scenarios.

Air pump operated at 25L/min for 35 hours. This modification is not a Dioxins TO-9 (Modified for indoor air) proven method. To be conducted during the Pilot Clean-up study only for worst case scenarios.

Silica, calcite, Air pump operated at 2.5L/min for 8 hours to achieve the COPC NIOSH 7500 gypsum wkgroup PQL Assumed that it behaves the same as asbestos, samples will be MMVF NIOSH 7400 HVAC avatama and AC combined with the asbestos sampling. units (collection of bulk dust Bulk samples will be collected from HVAC or AC window type unit Bulk Oust sample from the unit air Asbestos Bulk Sample filters, shaken into a plastic bag and transferred into the sample filters). Background study container. only. Lead (If the volume required is not sufficient for all analyses, the sample Bulk Sample will be analyzed for asbestos only. (If the volume required is not sufficient for all analyses, the sample PAHs Bulk Sample will be analyzed for asbestos only.

NYC-WTC_000407866

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407866Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Sampling procedures for WTC indoor monitoring

NYC-WTC_000204871

Document outlining analytical procedures and standards for collecting asbestos and lead samples from indoor surfaces during World Trade Center cleanup studies.

Similar indexed content

Compare copies and versions →