NYC-WTC_000362715
Chain-of-custody documenting pre-bid and monitoring requirements for WTC-LBA project.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Pre-bid conference notice and background for asbestos abatement at 114 Liberty Street.
NYC-WTC_000407465–000407470OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
»
4. Sampling equipment shall be placed at representative locations and away from obstruction. Sampling cassette must be placed on a tripod and not taped to existing surfaces. All air sampling equipment shall be pre- and post- calibrated to insure accurate air sampling volumes.
5. The Air Sampling Technician shall perform clearance air sampling after the areas are free of dust accumulations as determined by the Project Monitor. All surfaces must be completely dry prior to the start of sampling. Clearance air sampling shall be performed at each apartment. Five samples shall be collected in each apartment and two samples shall be collected at the first floor lobby. The elevator shaft shall be cleared separately. Clearance air monitoring shall be performed after the completion of all clean up activities at the work site. Clearance air sampling shall be aggressive and performed in accordance with Title 15, Chapter 1 of the RCNY Section 1-43 (a)-(d).
6. Clearance air samples shall be collected in accordance with the procedures specified in the NIOSH 7400 Method. The flow rate for collection of air samples shall be at least 10 liters per minute and no more than 15 liters per minute. Air sampling cassettes must be monitored to ensure the filters do not develop dark spots that would indicate clogging. The minimum sampling volume is 3600 liters. If clogging develops, the cassette must be changed.
7. All clearance air samples and completed chain of custody forms must be transported to the laboratory immediately after sampling is completed.
Clearance Criteria
1. The following clearance levels have been established by the USEPA for clean up activities resulting from the collapse of the WTC.
Table 2: Clearance Criteria Parameter Clearance Level Note Asbestos in air 0.0009 f/cc PCMe Primary clearance level Lead in settled dust <25 pg/tf Primary clearance level Dioxin in settled dust <4ng/m^ Primary clearance level Fibrous glass in air <0.01 f/cc Secondary clearance level Crystalline silica in air Ipg/m^ Secondary clearance level PAHs in settled dust <0.3 mg/m" Primary clearance level
Cleaning shall not be considered complete unless the primary clearance levels are achieved (see Table 2). The apartment will be re-cleaned and retested if the primary clearance levels are not achieved. These clearance levels may be re-evaluated and revised if determined necessary based on field conditions and analytical limitations. Secondary clearance levels shall be considered in determining the need for additional cleanup, however failure to meet the secondary clearance levels does not automatically trigger the re-cleaning. In the event re-cleaning is required, ressampljng shall be performed immediately upon completion of the cleaning.
Project Monitoring
1. The project monitor shall provide oversight of clean-up activities to ensure compliance with project specifications, tenants authorizations, and applicable rules and regulations. The project monitor 5 of 6
CITY_DEP_WORBY_CANNATA_SUBP_000030765
NYC-WTC_000407469
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000362715
Chain-of-custody documenting pre-bid and monitoring requirements for WTC-LBA project.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362696
Chain-of-custody document detailing asbestos abatement scope and on-site monitoring plan for 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209413
Statement of work describing requirements for environmental sampling and air monitoring during interior cleaning at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407471
Scope of work and monitoring plan for asbestos cleaning at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362684
Document detailing scope of asbestos-related air monitoring and site personnel requirements.
13 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362709
Chain-of-custody describing scope of asbestos monitoring and interior cleaning at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407447
Scope of work and monitoring plan for asbestos cleaning at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407459
Scope of work and monitoring plan for asbestos cleaning at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407453
Scope of work and monitoring plan for asbestos cleaning at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195796
Document outlining requirements for a pre-bid conference regarding asbestos abatement and air monitoring at a World Trade Center facility.
12 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155453
Discussion regarding corrections to asbestos sampling flow rate language in the 114 Liberty Street work plan.
13 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155617
Distribution of revised draft scopes of work documents for the 114 Liberty Street project.
13 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000362715
Chain-of-custody documenting pre-bid and monitoring requirements for WTC-LBA project.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162860
Revised scopes of work documents for 114 Liberty Street project.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155635
Submission of contract changes to scope documents awaiting final approval and bidder lists.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362696
Chain-of-custody document detailing asbestos abatement scope and on-site monitoring plan for 114 Liberty Street.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407471
Scope of work and monitoring plan for asbestos cleaning at 114 Liberty Street.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209413
Statement of work describing requirements for environmental sampling and air monitoring during interior cleaning at 114 Liberty Street.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000362715
Chain-of-custody documenting pre-bid and monitoring requirements for WTC-LBA project.
Similar indexed content
NYC-WTC_000362696
Chain-of-custody document detailing asbestos abatement scope and on-site monitoring plan for 114 Liberty Street.
Similar indexed content
NYC-WTC_000209413
Statement of work describing requirements for environmental sampling and air monitoring during interior cleaning at 114 Liberty Street.
Similar indexed content
NYC-WTC_000407471
Scope of work and monitoring plan for asbestos cleaning at 114 Liberty Street.
Similar indexed content
NYC-WTC_000362684
Document detailing scope of asbestos-related air monitoring and site personnel requirements.
Similar indexed content