Bid meeting notice for WTC 114 Liberty Street project

Machine-extracted title · confidence 38%

Pre-bid conference notice and background for asbestos abatement at 114 Liberty Street.

NYC-WTC_000407465–000407470
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Dm Crystalline Silica Air samples NIOSH 7500 NIOSH 7500 (XRD) 14 days

Asbestos Air samples Collection using Asbestos Fiber Analysis by 1 day NIOSH 7400 Transmission Electron Microscopy (TEM) Performed by EPA 40 C^ Part 763 Final Rule (AHERA) [see Attachment 1 ] and NIOSH 7400 (PCM)

Asbestos Air Sample Collection and Analysis

1. All asbestos air sampling methodologies shall be in accordance with the applicable sections of Title 15, Chapter 1 of the Rules of the City of New York and AHERA. (see reference in Table 1)

2. Asbestos air samples shall be analyzed in accordance with EPA 40 CRF Part 763 Final Rule (AHERA) using a transmission electron microscope (TEM) and reported as shown in Attachment 1. For the TEM analysis, two size fractions should be reported, a fraction that represents fibers >0.5 microns and a fraction that represents fibers >5 microns. The fraction that represents the fibers >5 microns is considered to be the PCM equivalent (i.e., PCMe) that should be compared to the primary' clearance value of 0.0009 s/cc. In addition, the asbestos air samples shall be analyzed in accordance with NIOSH 7400 for standard PCM analysis. These results shall be reported on a separate sheet. The detection limit shall be 0.0004 f/cc.

3. A turnaround time of 24 hours is required for all samples.

Asbestos Air Monitoring

1. Five (5) ambient air samples shall be collected outside but in the general vicinity of the work site. Samplers shall be placed in reasonable proximity to the building and away from obstructions, vents, and drafts that may unduly affect airflow.

2. Five (5) air samples shall be collected per day during cleanup activities. The flow rate shall be set at the minimum collection flow rate specified by the manufacturer for the sampling pump. The flow’ rate shall not exceed 3 liters per minute. A minimum sampling volume of 3600 liters shall be collected.

Samples shall be collected at isolation barriers outside the work area, the clean room of the worker/waste decontamination facility, and outside of the building.

3. Sample collection methodologies shall be in accordance with Title 15, Chapter 1 of the Rules of the City of New York (RCNY) and AHERA regarding documentation and sample locations and the requirements set forth herein regarding the rates of flow; and required volumes to achieve the necessary analytical sensitivity. 4 of 6

CITY_DEP_WORBY_CANNATA_SUBP_000030764

NYC-WTC_000407468

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407468Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Chain of custody, WTC-LBA scope

NYC-WTC_000362715

Chain-of-custody documenting pre-bid and monitoring requirements for WTC-LBA project.

Similar indexed content

Compare copies and versions →