Wipe samples for [name] High School, 2002

Machine-extracted title · confidence 52%

ATC memo/letter reporting wipe-sample results for PCDD/PCDF at BOE location, Feb 2002.

NYC-WTC_000400825–000400827
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan February 19, 2002 Wipe Samples for Dioxins Page 2 Stuvvesant Hieh School ('Manhattan') ATC Project No. 15-19125-0246

Combustion of PCB-containing oils, such as during an electrical transformer fire, is known to produce dioxins. Burning of some plastics may also produce dioxins. Dioxins are toxic and are considered to be carcinogenic.

WIPE SAMPLING RESULTS

ATC submitted three wipe samples for PCDDs/PCDFs (plus one blank) to Pace for analysis. Samples were taken fi-om areas specified by the parents association consultant. The sample area for each sample was one square meter (1 m2). The areas sampled were:

• 1 st floor main entrance wall; • 2nd floor bridge entrance wall; • Mixed air plenum - HVAC#1.

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 tetrachloro-dibehzp-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analytical results for each sample. Copies of the draft analysis reports are attached. The results of the samples are shown in the following table.

DIOXIN WIPE SAMPLE RESULTS 2,3, 7, 8 TCDD EQUIVALENTS - Nanograms per square meter (ng/m^) htWr.:'“ ■“>'' • '■'fY , LOCATION -

0.00

0.000044

0.00072

0.00

The New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^). The New York State Department of Environmental Conservation (NYSDEC) has set 0.0006 parts per million (ppm) as the allowable concentration of dioxin in soil. The EPA has established a residential clean-up goal of 1 part per billion (ppb).

The levels found in these.samples are below the NYSDOH guideline of 25 ng/m^.

CITY_21MC100_002896353

NYC-WTC_000400826

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000400826Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000238251

Laboratory report on dioxin and dibenzofuran contamination at Stuyvesant High School from late January 2002 sampling.

Similar indexed content

Compare copies and versions →