NYC 9/11 Public Portal Document
104 East 25th St
New York. New York 10010
www.atc- en vi ro .com
212,353.8280
Fax 212.353.8306
ASSOCIATES INC.
February 19, 2002
Mr. Bernard P. Orlan
Director, Environmental Health & Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101 -4008
Re: Wipe Samples for Dioxins
Stuyvesant BUigh School
345 Chambers Street
New York, New York
ATC Project No. 15-19125-0246
Dear Mr. Orlan;
ATC Associates Inc. (ATC) is pleased to provide this report of the results of the wipe-samples .
■ for polychlorinated dibenzo-p-dioxins (PCDDs)and dibenzofurans (PCDFs) collected on January
23,2002, at the referenced location. The New York City Board of Education (BOE) requested
these samples to evaluate possible contamination in the school building per the recommendation
of H. A. Bader, consultant to the parents association.
SCOPE OF WORK
Wagdi Abdelshahid, Industrial Hygienist of ATC’s New York City office, collected the samples.
The samples were collected using gauze pads and hexane as a solvent. The solvent was provided
and samples were analyzed by Pace Analytical Services, Inc. (Pace) of Minneapolis, MN, a
laboratory experienced in dioxin analysis. The analysis was performed by modified EPA
Method 8290 using combined capillary column gas chromatography/high resolution mass
spectrometry.
The sampling was performed consistent with generally accepted industrial hygiene practices. .
There were inherent limitations created by constraints of time, operational and work practice
variability, variations in contaminant concentrations, and sampling and analytical accuracy. The
results of the sampling represent conditions found on the dates the samples were collected.
SUBSTANCE DESCRIPTION
“Dioxins” or “dioxin” is a name used for a group of chlorinated multi-ringed organic compounds
that includes polychlorinated dibenzo dioxins (PCDDs) and polychlorinated dibenzo furans
(PCDFs). They are related to polychlorinated biphenyls (PCBs). PCDDs and PCDFs are not
produced commercially except for research purposes. They occur as trace level by-products of
combustion and industrial chemical processes.
CITY_21MC100_002896352
NYC-WTC_000400825
OCR can misread numbers and units. Confirm readings against the page image before using them.