Wipe samples for leadership school, ATC, 2002

Machine-extracted title · confidence 29%

ATC report of wipe samples for dioxins/furans at a NYC BOE school in 2002.

NYC-WTC_000240272–000240274
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Crlan January 25, 2002 Wipe Samples for Dioxins Page 2 H. S. for Leadership & Public Service (894M) ATC Project No. 15-19125-0290

Combustion of PCB-containing oils, such as during an electrical transformer fire, is known to produce dioxins. Burning of some plastics may also produce dioxins. Dioxins are toxic and are considered to be carcinogenic.

The New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square ineler (25 ng/m-). The New York State Department of Environmental Conservation (NYSDEC) has set 0.0006 parts per million (ppm) as the allowable concentration of dioxin in soil. The EPA has established a residential clean-up goal of 1 part per billion (ppb).

WIPE SAMPLING RESULTS

ATC submitted nine (9) wipe samples for PCDDs/PCDFs (plus one blank) to Pace for analysis. A copy of the laboratory report is provided in Attachment 1. Samples were taken from areas specified by the parents association consultant. The sample area was one square meter (m^). The sample locations and the areas are shown in the table as well as the results

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analytical results for each sample. A copy of the analytical laboratory' report is attached.

DIOXIN WIPE SAMPLE RESULTS (2,3, 7, 8 TCDD EQUIVALENTS) W j (iig/m^)" -* Ca.feteria Serving Window/DXl (niTT Library table - north/DX2 Room 1106 floor - south/DX3 0.017 Room 903 floor - north/DX4 0.014 Room 715 floor - south/DX5 0.00053 Room 503 floor - north/DX6 0.0042 Hallway 3rd floor - south/DX7 0.0011 Main Lobby - floor/DX8 0.062 Field Blank/DX9 0.00019

The concentrations on indoor surfaces ranged from 0.00053 to 0.062 nanograms per square meter (ng/m^). I'hc levels found in all of these samples are below the NYSDOH guideline of 25 ng/m^.

CONFIDENTIAL, CITY_21MC100_003432034 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240273

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240273Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →