Wipe sample results, dioxins, PS 89M, 2002

Machine-extracted title · confidence 52%

Wipe samples for dioxins from PS 89M, February 2002, ATC/BOE.

NYC-WTC_000249250–000249252
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan Febnuarj' 20, 2002 Wipe Samples for Dioxins Page 2 P. S. 89 (Manhattan) ATC Project No. 15-19125-0297

Combustion of PCB-containing oils, such as during an electncal transformer fire, is known to produce dioxins. Burning of some plastics may also produce dioxins. Dioxins are toxic and are considered to be carcinogenic.

The New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NY SDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^). The New York State Department of Environmental Conservation (NYSDEC) has set 0.0006 parts per million (ppm) as the allowable concentration of dioxin in soil. The EPA has established a residential clean-up goal of 1 part per billion (ppb).

WIPE SAMPLING RESULTS

ATC submitted three (3) wipe samples for PCDDs/PCDFs (plus one blank) to Pace for analysis. Copies of the draft laboratory analysis results are provided in Attachment 1. Samples were taken from areas specified by the parents association consultant. The sample area was one square meter (m2).

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analytical results for each sample. The sample locations and the results are shown in the table;

DIOXIN WIPE SAMPLE RESULTS (2,3, 7, 8 TCDD EQUIVALENTS) January 25, 2002

1st Floor Hallway-north/DXl 1st Floor Hallway-south/DX2 0.00014

2'^d Floor Hallway near Staircase/DX3 0.00038

Field Blank/DX4 0.00

The concentrations on indoor surfaces ranged from 0.00014 to 0.00038 nanograms per square meter (ng/m2). The dioxin concentrations in these sample are below the NYSDOH guideline.

It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in these samples were deposited. Dioxin samples were not collected from these locations prior to December 20, 2001.

CONFIDENTIAL, CITY_21MC100_010729758 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000249251

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000249251Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Wipe samples for dioxins, PS 89M, Jan 2002

NYC-WTC_000202101

Letter report from ATC Associates providing results for polychlorinated dibenzo-p-dioxins and furans wipe samples collected at PS 89M on January 25, 2002.

Similar indexed content

Compare copies and versions →