NYC 9/11 Public Portal Document
< UWO /-UtUIJtlVUI WVI VIVOMi
1700 Elm Street - Suite 200
Minneapolis, MN 55414
7 /ZpaceAnalytical"
r
Tel: 612-607-1700
Fax: 612-607-6444
Method 8290 Analysis Results
Client - ATC ASSOCIATES
Client's Sample ID ATC-0507-234M-DX1
Lab Sample ID 103537163
Filename U20605A_08
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 05/07/2002
ICAL Date 04/16/2002 Received 05/14/2002
CCal Filename(s) U20605A_03 & U20605A_18 Extracted 05/31/2002
Method Blank ID BLANK-1649 Analyzed 06/05/2002 22:26
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0053 — 0.0064 JA 2,3,7,8-TCDF-13C 2.00 58
Total TCDF 0.0990 -- 0.0020 2,3,7,8-TCDD-13C 2.00 62
J
1,2,3,7,8-PeCDF-13C 2.00 60
2,3,7,8-TCDD ND 0.0052 A 2,3,4,7,8-PeCDF-13C 2.00 59
Total TCDD 0.1400 0.0020 1,2,3,7,8-PeCDD-13C 2.00 61
1,2,3,4,7,8-HxCDF-13C 2.00 78
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 69
2.3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 72
Total PeCDF 0.0240 0.0100 J 1,2,3,7,8,9-HxCDF-13C 2.00 77
1,2,3,4,7,8-HxCDD-13C 2.00 83
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 61
Total PeCDD 0.0510 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 73
1,2,3,4,7,8,9-HpCDF-13C 2.00 78
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 84
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 77
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 0.0150 0.0100 J 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7.8-TCDD-37CI4 0.20 67
1,2,3,6,7,8-HxCDD ND 0.0100
1.2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.0430 0.0100 J
1.2,3,4,6,7,8-HpCDF 0.0200 0.0100 J Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0110 A Equivalence: 0.0017 ng/m2
Total HpCDF 0.0360 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0460 0.0100 J
Total HpCDD 0.1000 0.0100
OCDF 0.0240 0.0200 J
OCDD 0.5000 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals Include 2,3,7,8-substituted isomeis) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Correentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1057493
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Paco Analytical Services, Inc.
CITY_21MC100_002889439