PSI report covering Jan 26, 2002; VOCs and other parameters within guidelines.

NYC-WTC_000390177–000390179
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 1 Respirable Dust & Silica Air Sampling (January 26"", 2002) Sample No. Location Respirable Dust Respirable Silica RS-01 Trailer #101 <0.004 mg/m <0.0100 mg/m RS-02 Trailer #103________________ <0.004 mg/m <0.0100 m^m’ RS-03 Trailer #105 <0.004 mg/m <0.0100 mg/m’ RS-04 Trailer# 107_______________ 0.0533 m^m^ ~ 0.0149 mg^’ RS-05 Trailer# 109 <0.004 mg/m 0.0236 m^m’ ~ RS-06 Trailer# 111________________ 1.1489 m^m^~ <0.0100 mg/m RS-07 Outside Trailer # 101 - West side 1.0133 mg/m^ <0.0100 RS-FBL-1 Field Blank 1 Not detected <0.0100 mg/m

Air Sampling for Total Dust

PSI collected 7 representative air samples on January 26“’, 2002, one from each of six of the Traders and one from a nearby outside area. Samples were coUected and analyzed by NIOSH Method 0500 to determine ambient or background airborne total dust concentrations. Total dust concentrations ranged from <0.004 mg/m’ to 0.759 mg/m’ which are below the OSHA limit of 15 mg/m’ and the ACGIH limit of 10 mg/m’. Analytical results are shown below in Table 2.

Table 2 Total Dust Air Sanqjling (January 2^^, 2002) Sample No. Location Total Dust TD-01 Trailer# 101 0.759 mg/m’ TD-02 TraUer# 103 0.130 m^'m^ TD-03 Trailer# 105________________ 0.083 mg/m’ TD-04 Trader# 107________________ <0.004 mg/m’ TD-05 Trailer #109 0.022 mg/m’ TD-06 Trader #111________________ <0.004 mg/m’ TD-07 Outside Trader # 101 - West side 0.077 mg/m’ TD-FBL-1 Field Blank 1 Not detected

Volatile Organic Compounds fVOC’s)

Measurement of total VOC’s is used to determine general quality of air associated with the level of volatile organic compounds. 25 samples for volatile organic compounds were collected with a MINIRAE 2000, direct reading photoionization detector on January 26“', 2002. Samples were collected within the North Building, the South Building and Trailers. Outside air background samples were also collected. The Indoor Air Quality Association (Standard lAQA #95-1) recommends levels be at or below 3.0 ppm for acceptable indoor air quality. Momentary spikes above 3 ppm related to janitorial operations are considered acceptable. The data indicated that total VOC’s were not detected in 23 of the areas sampled. VOC’s were detected in 2 of the samples, however at a concentration of 0.1 ppm the levels are well below the lAQA guideline. Please refer to Table 3 for measured results.

CITY_21MC100_008854625

NYC-WTC_000390178

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390178Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →