Table 1 Respirable Dust & Silica Air Sampling(January 26",2002)
Sample No. Location Respirable Dust Respirable Silica
RS-01 Trailer # 101 <0.004 m <0.0100 m
RS-02 Trailer # 103 <0.004 m <0.0100 m
RS-03 Trailer # 105 <0.004 m <0.0100 mg/m3
RS-04 Trailer # 107 0.0533 mg/m3 0.0149 m3
RS-05 Trailer # 109 <0.004 m 0.0236 m
RS-06 Trailer # 111 1.1489 m <0.0100 m
RS-07 Outside Trailer # 101— West side 1.0133 m <0.0100 In
RS-FBL-1 Field Blank 1 Not detected <0.0100 mg/m3
Air Sampling for Total Dust
PSI collected 7 representative air samples on January 26th, 2002, one from each of six of the
Trailers and one from a nearby outside area. Samples were collected and analyzed by NIOSH
Method 0500 to determine ambient or background airborne total dust concentrations. Total
dust concentrations ranged from <0.004 mg/m3 to 0.759 mg/m3 which are below the OSHA
limit of 15 mg/m3 and the ACGIH limit of 10 mg/m3. Analytical results are shown below in
Table 2.
Table 2 Total Dust Air Sampling (January 26`", 2002)
Sample No. Location Total Dust
TD-01 Trailer # 101 0.759 mg/m3
TD-02 Trailer # 103 0.130 mg/m3
TD-03 Trailer # 105 0.083 mg/m3
TD-04 Trailer # 107 <0.004 mg/m3
TD-05 Trailer #109 0.022 m
TD-06 Trailer #111 <0.004 m
TD-07 Outside Trailer # 101— West side 0.077 m
TD-FBL-1 Field Blank 1 Not detected
Volatile Organic Compounds (VOC's)
Measurement of total VOC's is used to determine general quality of air associated with the level
of volatile organic compounds. 25 samples for volatile organic compounds were collected with
a MINIRAE 2000, direct reading photoionization detector on January 26th, 2002. Samples were
collected within the North Building, the South Building and Trailers. Outside air background
samples were also collected. The Indoor Air Quality Association (Standard IAQA #95-1)
recommends levels be at or below 3.0 ppm for acceptable indoor air quality. Momentary spikes
above 3 ppm related to janitorial operations are considered acceptable. The data indicated that
total VOC's were not detected in 23 of the areas sampled. VOC's were detected in 2 of the
samples, however at a concentration of 0.1 ppm the levels are well below the IAQA guideline.
Please refer to Table 3 for measured results.
NYC-WTC 000106390