NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

BMCC environmental testing memo, Dec 2001

Machine-extracted title · confidence 34%

Monthly environmental testing coordination for BMCC; access issues acknowledged; schedules for ongoing testing.

NYC-WTC_000390171–000390174
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NO.096 5004

Pb-16 Floor-5'’^ Fk. Escalator landing <10.0 ug/tf Pb-17 Floor-4®Flr. Entrance to LibrLy <10.0 Pb-18 Floor-Hallway by Rm S368 <10.0 Pb-19 Floor-Hallway by Rm S206A <10.0 Pb-20 Floor-2"^ Fir. Cafeteria entrance <10.0 Pb-21 Floor-Hallway by Rm, S165 <10.0 u^fe Pb-22 Field Blank after <10.0 u^wi^ Tab1a2Lead SamjfllMg

Air Sampling-Nuisance Dust A Silica PSI collected 2 representative air samples from each odd. numbered floor of the north and south buildings. Samples were collected from common corridors, escalators, the Gymnasium and Theater 3. A total of 16 samples were collected and analyzed by NIOSH Method 7500 to determine ambient or background airborne nuisance dust and respirable silica concentrations. Nuisance dust concentrations ranged from 0.057S mg/m^ to 0.6778 mgZm’ which are below the OSHA limit of 5 mg/m^ and the ACGIH limit of 3 mg/m’. Respirable silica was detected in two (2) samples and not detected in fourteen (14) samples. Concentrations in the two samples detected were 0.0213 mg/m^ and 0.0276 mg/m’, which are below the NIOSH limit of 0,05 mg/m’ and the ACGIH limit of 0.1 rog/m’.

Refear to the attached laboratory analysis conducted by BMSL Laboratories for the analytical results.

Airborne Metals Air samples were collected on December 15* from each floor in the North Building and the South Building and from eight (8) Trailers. A total of 23 samples were collected and analyzed by NIOSH Method 7300 to detcraiinfi ambient or background levels of airborne lead, chromium, arsenic and iron concentrations. AU samples indicated levels below toe NIOSH or ACGIH limits established for airborne concentrations of these metals.

Refer to the attached laboratory analysis conducted by American Analytical Laboratories for the analytical results. Volatile, dG aonnda Measurement of total VOC’s is used to de ine general quality of air associated with the level of volatile organic compounds. Samples for volatile organic compounds were collected with a MINIRAE 2000, direct reading photoionization detector. Samples were collected within the North and South Buildings and the Trailers, as well as outdoors. The Indoor Air Quality Association (Standard lAQA #95-1) recommends levels bo maintained al or below 3,0 ppm for acceptable indoor air quality. The data indicated that total VOC’s were not detected within the areas sampled. Please refer to Table 3 for measured results.

Sample No. Location VOCppm V-01 7* Floor North Room 779 0.0 V-02 6“ Floor North Hallway by Room 635 0.0

i i

CITY_21MC100_008854620

NYC-WTC_000390173

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390173Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

BMCC testing report, Jan 2002

NYC-WTC_000390177

PSI report covering Jan 26, 2002; VOCs and other parameters within guidelines.

Similar indexed content

Compare copies and versions →