Table 2Lead line Sampling
Sample No. Location Results - Lead Concentration
Pb-01 Field Blank prior <10.0 ug/wipe
Pb-02 Floor - Hallway by Rm. N736 <10.0 u ft
Pb-03 Floor-Rm. N635 North Center <10.0 u ft2
Pb-04 Floor-Hallway by Rm N501 <10.0 ug/ft2
Pb-05 Floor-Lobby by Rm N404 <10.0. u ft
Pb-06 Floor-Across from Rm. N301 <10.0 u ft2
Pb-07 Floor-Passageway between N & S bldgs. <10.0 u ft2
Pb-08 Floor-Lobby by Rm N212 <10.0 u ft2
Pb-09 Floor-Gym by NW entrance <10.0 u ft
Pb-10 Floor-2" Flr. Lobby NW entrance <10.0 u ft2
Pb-11 Floor-1' Flr. By West entrance <10.0 u ft2
Pb-12 Field Blank after <10.0 ug/wipe
Pb-13 Field Blank prior <10.0 ug/wipe
Pb-14 Floor-Hallway by Rm S736A <10.0 u ft
Pb-15 Floor-Room S602 <10.0 u ft2
Pb-16 Floor 5th Flr. Escalator landing <10.0 u ft2
Pb-17 Floor 4th Flr. Entrance to Library <10.0 u ft2
Pb-18 Floor-Hallway by Rm. S368 <10.0 u ft2
Pb-19 Floor-Hallway by Rm. S206A <10.0 u ft2
Pb-20 Floor-2°d Flr. Cafeteria entrance <10.0 u ft
Pb-21 Floor-Hallway by Rm S165 <10.0 u ft2
Pb-22 Field Blank after <10.0 ug/wipe
Air Sampling for Nuisance Dust & Silica
PSI collected 2 representative air samples from each odd numbered floor of the North and South
Buildings on December 20th, 2001. Samples were collected from common corridors, escalators,
the Gymnasium and Theater 3. A total of 16 samples were collected and analyzed by National
Institute for Occupational Safety and Health (NIOSH) Method 7500 to determine ambient or
background airborne nuisance dust and respirable silica concentrations. Nuisance dust
concentrations ranged from 0.0578 mg/m3 to 0.6778 mg/m3 which are below the Occupational
Safety and Health Administration (OSHA) limit of 5 mg/m3 and the American Conference of
Governmental Industrial Hygienists (ACGIH) limit of 3 mg/m3. Respirable silica was detected in
two (2) samples and not detected in fourteen (14) samples. Concentrations in the two samples
detected were 0.0213 mg/m3 and 0.0276 mg/m3, which are below the NIOSH limit of 0.05
mg/m3 and the ACGIH limit of 0.1 mg/m3. Refer to the attached laboratory analysis conducted
by EMSL Laboratories for the analytical results presented in Appendix C.
Sampling for Airborne Metals
Concern regarding the cutting and transport of WTC structural members adjacent to the College
prompted investigation for potential airborne metals. Air samples were collected on December
15th from each floor in the North Building and South Building and from eight (8) Trailers. A
total of 23 samples were collected and analyzed by NIOSH Method 7300 to determine ambient
NYC-WTC 000106407
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000106407Source: NYC Law Department, mirrored locally