Environmental testing results, BMCC Dec 2001

Machine-extracted title · confidence 37%

PSI testing at BMCC trailers; rounds from Sep to Dec 2001; results follow-up noted.

NYC-WTC_000390168–000390170
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 2 Lead Wipe Sampling Sample No. Location Results - Lead Concentration Pb-01 Field Blank prior__________________ <10.0 ug/wipe_____________ Pb-02 Floor - Hallway by Rm. N736________ <10.0 u^ft^ Pb-03 Floor-Rm. N635 North Center <10.0ug/ft^_______________ Pb-04 Floor-Hallway by Rm. N501_________ <10.0 u^ft^ Pb-05 Floor-Lobby by Rm. N404___________ <10.0 u^ft^ Pb-06 Floor-Across from Rm. N301 <10.0ug/ft^_______________ Pb-07 Floor-Passageway between N & S bldgs. <10.0 u^ft^ Pb-08 Floor-Lobby by Rm. N212___________ <10.0 u^ft^ Pb-09 Floor-Gym by NW entrance__________ <10.0ug/ft^_______________ Pb-10 Floor-2”^ Fir. Lobby NW entrance <10.0 u^ft^ Pb-11 Floor-Fir. By West entrance_______ <10.0 u^ft^ Pb-12 Field Blank after <10.0 ug/wipe Pb-13 Field Blank prior__________________ <10.0 ug/wipe __________ Pb-14 Floor-Hallway by Rm. S736A________ <10.0 u^ft^ Pb-15 Floor-Room S602_________________ <I0.0ug/ft^_______________ Pb-16 Floor-5*^ Fir. Escalator landing <10.0 ug/ft_______________ Pb-17 Floor-4* Fir. Entrance to Librmy <10.0 ug/ft^_______________ Pb-18 Floor-Hallway by Rm. S368__________ <10.0 u^ft^ Pb-19 Floor-Hallway by Rm. S206A________ <10.0ug/ft^_______________ Pb-20 Floor-2''^ Fir. Cafeteria entrance_______ <10.0ug/ft^_______________ Pb-21 Floor-Hallway by Rm. SI65__________ <10.0ug/ft^_______________ Pb-22 Field Blank after <10.0 ug/wipe

Air Sampling for Nuisance Dust & Silica PSI collected 2 representative air samples from each odd numbered floor of the North and South Buildings on December 2O'\ 2001. Samples were collected from common corridors, escalators, the Gymnasium and Theater 3. A total of 16 samples were collected and analyzed by National Institute for Occupational Safety and Health (NIOSH) Method 7500 to determine ambient or background airborne nuisance dust and respirable silica concentrations. Nuisance dust concentrations ranged from 0.0578 mg/m’ to 0.6778 mg/m^ which are below the Occupational Safety and Health Administration (OSHA) limit of 5 mg/m* and the American Conference of Governmental Industrial Hygienists (ACGIH) limit of 3 mg/m^. Respirable silica was detected in two (2) samples and not detected in fourteen (14) samples. Concentrations in the two samples detected were 0.0213 mg/m^ and 0.0276 mg/m^, which are below the NIOSH limit of 0.05 mg/m^ and the ACGIH limit of 0.1 mg/m\ Refer to the attached laboratory analysis conducted by EMSL Laboratories for the analytical results presented in Appendix C.

Sampling for Airborne Metals Concern regarding the cutting and transport of WTC structural members adjacent to the College prompted investigation for potential airborne metals. Air samples were collected on December 15'*’ from each floor in the North Building and South Building and from eight (8) Trailers. A total of 23 samples were collected and analyzed by NIOSH Method 7300 to determine ambient

CITY_21MC1OO_OO8854616

NYC-WTC_000390169

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390169Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →