Bulk sample analysis report, 14-22 [name] St, Manhattan

Machine-extracted title · confidence 42%

Bulk sample analysis results for NYC-DCAS at 14-22 [name], Manhattan.

NYC-WTC_000386164
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUANTS 35-40 36th Street Long Island City NewYork. 11106 Tel: (718)729-1937 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID- 433 44A 443 45 A 453 Lab Sample ID- 010905B-260 010905B-261 010905B-262 0109053-263 010905B-264

Sample Location Roof'D" Roof"D" Roof'D" Roof'D" Roof'D"

Homogeneity Yes Yes Yes Yes Yes

Sample Description Base Flashing Base Flashing Base Flashing Base Flashing Base Flashing 2nd Laver 1st Layer 2nd Ld\er 1st Layer 2nd Layer

Color Blk Blk Blk Blk Blk

Texture Mixed Mixed Mixed Mixed Mixed

Sample Treatment Acid Digestion Acid Digestion Acid Digestion Acid Digestion Acid Digestion & Ashing & Ashing & Ashing & Ashing & Ashing Asbestos Present (Type & Percent) 5 20%CHR 12 25%CHR 6 30%CHR 14 35%CHR 4 48%CHR Total Percent Asbestos: 5.20% 12.25% 6.30% 14.35% 4.48%

Other Fibr Mat (Type & Percent) 0% 0% 0% 0% 0% Non Fibr Mat (Percent). 94.80% 87 75% 93 70% 85 65% 95.52% Date Received 9/5/01 Date of Analysis 9/6/01 Date of Report:

Analyst: 9/7/01

TVA . I )l /XT/IUc i Lab Manager: \ > ■ J. p M Ulanecki David Chen * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP # 11273 NIST-NVLAP ff 102047 AIHA U; 100269

21

NYC-WTC_000386164

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386164Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →